{"product_id":"honeywell-fta-t-16-16-channel-fail-safe-digital-input-module","title":"Honeywell FTA-T-16 16-Channel Fail-Safe Digital Input Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell FTA-T-16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 16-channel fail-safe active digital input module designed for Honeywell Safety Manager and FSC platforms. It provides reliable acquisition of discrete signals from field devices such as switches, sensors, and safety interlocks, while maintaining fault tolerance and line monitoring for safety-critical operations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFail-Safe Operation: Maintains functional integrity even in case of system or wiring faults\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLine Fault Detection: Monitors wiring conditions to prevent unsafe system behavior\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh Reliability: Engineered for safety-critical environments including petrochemical, power generation, and industrial manufacturing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModular Integration: Compatible with Honeywell Safety Manager and FSC control platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact \u0026amp; Durable: Small footprint with rugged design suitable for harsh industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlexible Input Options: Supports both 24 VDC and 120 VAC signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eHoneywell FTA-T-16\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e16-Channel Fail-Safe Active Digital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 discrete inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC \/ 120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e10 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Monitoring\u003c\/td\u003e\n\u003ctd\u003eDetects wiring faults, configurable fail-safe\/fail-operate modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e94 × 95.3 × 57.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.63 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e–20°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e–40°C to +105°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDiscrete signal acquisition from safety devices and field switches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety-critical monitoring and control in petrochemical, energy, and industrial automation environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration with Honeywell Safety Manager and FSC platforms for industrial safety systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement or upgrade of legacy fail-safe digital input modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can FTA-T-16 detect wiring faults automatically?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it includes line monitoring to identify wiring errors and prevent unsafe conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What types of signals are supported?\u003c\/strong\u003e\u003cbr\u003eA: Both 24 VDC and 120 VAC digital signals from pushbuttons, limit switches, and safety sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it suitable for harsh industrial environments?\u003c\/strong\u003e\u003cbr\u003eA: Absolutely, it is compact, rugged, and operates reliably from –20°C to +65°C, with storage tolerance to –40°C to +105°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which Honeywell platforms is it compatible with?\u003c\/strong\u003e\u003cbr\u003eA: Fully compatible with Honeywell Safety Manager and FSC safety control systems.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43884548980824,"sku":"FTA-T-16","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/FTA-T-16.jpg?v=1773818839","url":"https:\/\/www.industriaxplc.com\/products\/honeywell-fta-t-16-16-channel-fail-safe-digital-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}