{"product_id":"honeywell-fc-tuio11-safety-universal-i-o-module","title":"Honeywell FC-TUIO11 Safety Universal I\/O Module","description":"\u003ch2\u003eHoneywell FC-TUIO11 Safety Universal I\/O Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for universal field signal execution in Honeywell Safety Manager and Fail Safe Controller systems, the \u003cstrong\u003eHoneywell FC-TUIO11\u003c\/strong\u003e (\u003cstrong\u003eFC-TUIO11\u003c\/strong\u003e Safety Universal I\/O Module) provides direct physical and electrical interface functions for safety-related input and output channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-TUIO11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSafety Universal I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e19.1 x 18.8 x 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.22 W at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e55 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Safe Voltage (Um)\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUo\u003c\/td\u003e\n\u003ctd\u003e25.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIo\u003c\/td\u003e\n\u003ctd\u003e113.13 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePo\u003c\/td\u003e\n\u003ctd\u003e712.7 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Signal Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe FC-TUIO11 supports universal I\/O signal handling within Honeywell safety control architectures. The module provides field circuit connection capability with defined electrical safety parameters, including 250 V maximum safe voltage and intrinsically safe output limits of 25.2 V, 113.13 mA, and 712.7 mW.\u003c\/p\u003e\n\u003cp\u003eFurthermore, Honeywell Safety Manager configurations can apply channel-to-channel isolation practices to maintain separation between field wiring circuits. The module design supports integration with process instrumentation interfaces where signal conditioning and controlled electrical characteristics are required.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power supply does the Honeywell FC-TUIO11 require?\u003cbr\u003eA: The FC-TUIO11 operates from a 24 VDC power supply and consumes 55 mA at rated voltage.\u003c\/p\u003e\n\u003cp\u003eQ: What are the maximum electrical safety parameters of the FC-TUIO11?\u003cbr\u003eA: The module specifies a maximum safe voltage (Um) of 250 V, with Uo of 25.2 V, Io of 113.13 mA, and Po of 712.7 mW.\u003c\/p\u003e\n\u003cp\u003eQ: Can the FC-TUIO11 be installed in redundant safety controller systems?\u003cbr\u003eA: The module is designed for Honeywell safety control platforms. Redundancy configuration depends on the controller architecture and system engineering requirements.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the FC-TUIO11 inside the designated Honeywell safety controller chassis according to system hardware documentation.\u003c\/li\u003e\n\u003cli\u003eVerify that the 24 VDC supply polarity and voltage level match the module requirements before energizing the system.\u003c\/li\u003e\n\u003cli\u003eSeparate field signal wiring from high-voltage power cables to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the site grounding design and applicable industrial installation standards.\u003c\/li\u003e\n\u003cli\u003eConfirm terminal wiring, channel assignment, and safety circuit configuration before commissioning.\u003c\/li\u003e\n\u003cli\u003eCheck the module electrical parameters against connected field devices to maintain compliance with the specified Um, Uo, Io, and Po limits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44477070803032,"sku":"FC-TUIO11","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/FC-TUIO11-3.jpg?v=1785322381","url":"https:\/\/www.industriaxplc.com\/products\/honeywell-fc-tuio11-safety-universal-i-o-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}