{"product_id":"honeywell-fc-tsgas-1624-digital-input-field-termination-assembly","title":"Honeywell FC-TSGAS-1624 Digital Input Field Termination Assembly","description":"\u003ch2\u003eHoneywell FC-TSGAS-1624 Digital Input Field Termination Assembly\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-TSGAS-1624\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTSGAS-1624\u003c\/strong\u003e Digital Input Field Termination Assembly, provides direct physical signal termination and power distribution for safe gas and flame detector input circuits within Honeywell Safety Manager platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-TSGAS-1624\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Input Field Termination Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e22.6 x 7 x 5.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC external, 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Model\u003c\/td\u003e\n\u003ctd\u003eTSGAS-1624\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003e0-25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e500 ohm +\/- 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e0-4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Rating\u003c\/td\u003e\n\u003ctd\u003e500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Dimensions\u003c\/td\u003e\n\u003ctd\u003e5 x 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating AC\u003c\/td\u003e\n\u003ctd\u003e250 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating DC\u003c\/td\u003e\n\u003ctd\u003e300 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCE, TUV, UL, CSA, FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipment Location\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Instrument Signal Termination and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe FC-TSGAS-1624 supports Honeywell safety input architectures by terminating field transmitter signals and distributing external power to connected devices. Furthermore, each input channel processes 0-20 mA gas and flame detector signals through dedicated termination circuits.\u003c\/p\u003e\n\u003cp\u003eThe assembly provides transmitter power distribution with 500 mA fused protection for each connected field device. In addition, the 16-channel design reduces cabinet wiring complexity while maintaining separated field signal routing.\u003c\/p\u003e\n\u003cp\u003eFor Honeywell Safety Manager installations, the module supports channel-to-channel isolation practices required for process instrument interfaces. The assembly focuses on physical signal conditioning rather than controller logic execution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of field signals does the Honeywell FC-TSGAS-1624 accept?\u003cbr\u003eA: The FC-TSGAS-1624 accepts analog current input signals from safe gas and flame detector devices within the 0-25 mA input range.\u003c\/p\u003e\n\u003cp\u003eQ: Does the FC-TSGAS-1624 provide transmitter power distribution?\u003cbr\u003eA: Yes. The assembly distributes external 24 VDC power to field transmitters with 500 mA fused protection per output supply path.\u003c\/p\u003e\n\u003cp\u003eQ: How many input channels are available on this termination assembly?\u003cbr\u003eA: The FC-TSGAS-1624 provides 16 input channels for gas and flame detector field connections.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the FC-TSGAS-1624 inside the designated Honeywell Safety Manager cabinet or approved termination enclosure.\u003c\/li\u003e\n\u003cli\u003eVerify field wiring polarity before connecting current loop devices to the termination points.\u003c\/li\u003e\n\u003cli\u003eSeparate low-level instrument signal wiring from high-voltage power cables to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the system grounding design and maintain consistent shield termination practices.\u003c\/li\u003e\n\u003cli\u003eConfirm fuse installation matches the specified 500 mA rating before energizing field circuits.\u003c\/li\u003e\n\u003cli\u003eCheck terminal tightness and verify loop continuity before commissioning the connected detectors.\u003c\/li\u003e\n\u003cli\u003eFollow Honeywell cabinet layout requirements for ventilation, grounding, and module accessibility.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44480303071320,"sku":"FC-TSGAS-1624","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/FC-TSGAS-1624-3.jpg?v=1785406299","url":"https:\/\/www.industriaxplc.com\/products\/honeywell-fc-tsgas-1624-digital-input-field-termination-assembly","provider":"IndustriaX Limited","version":"1.0","type":"link"}