{"product_id":"honeywell-fc-psu-uni2450u-v1-0-experion-pks-industrial-power-module","title":"Honeywell FC-PSU-UNI2450U V1.0 | Experion PKS | Industrial Power Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Honeywell \u003cstrong\u003eFC-PSU-UNI2450U V1.0\u003c\/strong\u003e Power Module is a heavy-duty industrial-grade supply unit designed to deliver stable and reliable 24VDC power for distributed control systems (DCS), safety instrumented systems, and other mission-critical automation applications. Built for resilience, it combines advanced protection features with flexible operation to ensure uninterrupted performance in demanding environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e \u003cstrong\u003eFC-PSU-UNI2450U V1.0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Honeywell\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Power Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e Experion PKS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Brand New\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e DCS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOrigin:\u003c\/strong\u003e USA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 4.4 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 44 × 14.5 × 9 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHS Code:\u003c\/strong\u003e 8537101190\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMOQ:\u003c\/strong\u003e 1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLead Time:\u003c\/strong\u003e In Stock\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Interface:\u003c\/strong\u003e Ethernet Router\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStatus:\u003c\/strong\u003e Active (not discontinued)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFunctional Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eFC-PSU-UNI2450U V1.0\u003c\/strong\u003e module delivers up to 1200W output with intelligent current limiting and under-voltage alarms (\u0026lt;22V). It features dual over-voltage protection compliant with IEC 61508 functional safety standards, ensuring safe operation in critical control systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eKey features include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHot-swappable design with ON\/OFF switch and isolated connectors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOutput diode for parallel operation and 100ms holdup time during interruptions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eComprehensive safeguards against overloads and short-circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOperating temperature range: -5°C to +70°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCertifications: UL 508 and EN 61558-2-16.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOptional FA-PSU-UNI2450U variant with extended -40°C to +70°C range and Hazloc certification (ATEX, IECEx, CSA Zone 2).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFan monitoring with alarm functionality for enhanced reliability.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eContinuous process industries requiring uninterrupted power supply.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOil \u0026amp; gas refineries and chemical plants with strict safety requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePower generation facilities with high electrical noise environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAutomation systems where uptime and power quality directly impact productivity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the maximum output capacity of the FC-PSU-UNI2450U V1.0?\u003c\/strong\u003e  A: It provides up to 1200W regulated output with intelligent current limiting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can the unit be replaced while the system is live?\u003c\/strong\u003e  A: Yes, it supports hot-swapping with isolated connectors for safe replacement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What certifications does this module carry?\u003c\/strong\u003e  A: UL 508, EN 61558-2-16, and optional Hazloc certifications for explosive atmospheres.\u003c\/span\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43224413798488,"sku":"FC-PSU-UNI2450U V1.0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/honeywell-fc-psu-uni2450u-v1-0-power-module-q3xji15f1qw.png?v=1758525304","url":"https:\/\/www.industriaxplc.com\/products\/honeywell-fc-psu-uni2450u-v1-0-experion-pks-industrial-power-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}