{"product_id":"honeywell-cc-tdi230-series-c-high-voltage-digital-input-termination-assembly","title":"Honeywell CC-TDI230 Series C High Voltage Digital Input Termination Assembly","description":"\u003ch2\u003eHoneywell CC-TDI230 Series C High Voltage Digital Input Termination Assembly\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-voltage discrete signal termination in the Experion PKS platform, the \u003cstrong\u003eHoneywell CC-TDI230\u003c\/strong\u003e (\u003cstrong\u003eCC-TDI230\u003c\/strong\u003e High Voltage Digital Input Termination Assembly) provides direct electrical interface between 240 VAC field inputs and the CC-PDIH01 Digital Input Module. The assembly supports redundant I\/O architecture, optical isolation, and field wiring termination for 32 digital input channels.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe supplied documentation identifies \u003cstrong\u003eCC-TDI230\u003c\/strong\u003e as a single catalog model. No official suffix variants or ordering code matrix are specified for this product.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TDI230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified in the available documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSeries C High Voltage Digital Input Termination Assembly (IOTA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Module\u003c\/td\u003e\n\u003ctd\u003eCC-PDIH01 High Voltage Digital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series C I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e32 digital input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e240 VAC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e180 to 264 VAC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePick-up Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 180 VAC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop-out Voltage\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 50 VAC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSense Current (ON)\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.11 mA RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSense Current (OFF)\u003c\/td\u003e\n\u003ctd\u003eMaximum 0.32 mA RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Delay\u003c\/td\u003e\n\u003ctd\u003eMaximum 25 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC RMS or +\/- 1500 VDC field to logic common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Method\u003c\/td\u003e\n\u003ctd\u003eOptical isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOTA Width\u003c\/td\u003e\n\u003ctd\u003e12 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wiring\u003c\/td\u003e\n\u003ctd\u003eHigh-voltage digital input termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e12-inch IOTA assembly; other dimensions not specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation for Process Control I\/O\u003c\/h3\u003e\n\u003cp\u003eThe CC-TDI230 employs optical isolation between field wiring and logic common to separate high-voltage input circuits from the control electronics. This isolation is specified at 1500 VAC RMS or +\/- 1500 VDC and is intended to reduce electrical coupling between the field interface and the controller circuitry. When installed with the CC-PDIH01 module, the assembly supports redundant Series C I\/O configurations while maintaining independent field signal termination.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the CC-TDI230 support redundant I\/O operation?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The termination assembly is designed for use in redundant Series C I\/O configurations when paired with the compatible CC-PDIH01 Digital Input Module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the CC-TDI230 be connected directly to 240 VAC field signals?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The assembly is intended for nominal 240 VAC digital inputs with a specified operating range of 180 to 264 VAC RMS at 47 to 63 Hz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is hot swapping of the termination assembly specified?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The available documentation does not explicitly specify hot-swap capability for the IOTA. Installation and replacement should follow the applicable Experion PKS maintenance procedures.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that all field circuits are de-energized before connecting or disconnecting field wiring.\u003c\/li\u003e\n\u003cli\u003eInstall only with the compatible CC-PDIH01 High Voltage Digital Input Module specified for the Series C platform.\u003c\/li\u003e\n\u003cli\u003eRoute high-voltage input wiring separately from low-level signal and communication cables to minimize electrical interference.\u003c\/li\u003e\n\u003cli\u003eTerminate cable shields according to the plant grounding standard to avoid unwanted ground loops.\u003c\/li\u003e\n\u003cli\u003eConfirm the applied field voltage remains within the specified operating range before energizing the I\/O channel.\u003c\/li\u003e\n\u003cli\u003eAfter installation, verify channel indication and controller diagnostics before returning the system to service.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44306801590360,"sku":"CC-TDI230","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CC-TDI230-2.jpg?v=1782980310","url":"https:\/\/www.industriaxplc.com\/products\/honeywell-cc-tdi230-series-c-high-voltage-digital-input-termination-assembly","provider":"IndustriaX Limited","version":"1.0","type":"link"}