{"product_id":"honeywell-cc-paoh01-51405039-175-analog-output-module","title":"Honeywell CC-PAOH01 51405039-175 Analog Output Module","description":"\u003ch2\u003eHoneywell CC-PAOH01 51405039-175 Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for analog current signal generation in Experion PKS Series C I\/O architecture, the \u003cstrong\u003eHoneywell CC-PAOH01 51405039-175\u003c\/strong\u003e (\u003cstrong\u003e51405039-175\u003c\/strong\u003e Analog Output Module) provides direct physical\/electrical execution of 4-20 mA HART loop outputs for field actuator and final control element driving.\u003c\/p\u003e\n\u003cp\u003eThe module implements 16 independent current sourcing channels with configurable output behavior per channel, supporting HOLD LAST VALUE and SHED TO SAFE STATE (FAILOPT). Each channel continuously regulates loop current with internal diagnostics for open wire detection, output discrepancy monitoring, and HART-capable multivariable communication over the same 4-20 mA loop interface.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eNo validated manufacturer-specified suffix decomposition is provided for CC-PAOH01 51405039-175. The ordering code 51405039-175 is treated as a unique catalog identifier mapped to the CC-PAOH01 Series C analog output hardware instance.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-PAOH01 51405039-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e6 x 15.5 x 14.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified in provided data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.46 A at 24 VDC (module supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA HART Analog Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resistive Load\u003c\/td\u003e\n\u003ctd\u003e800 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Compliant Voltage\u003c\/td\u003e\n\u003ctd\u003e16 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Open Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e22 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Linearity\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.05% of Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibrated Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.35% of Full Scale at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.05% of Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd\u003e0.005% FS per deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHoneywell 4-20 mA HART Loop Execution Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe module operates as a loop-powered current sourcing device implementing 4-20 mA HART protocol signaling over each output channel. Each channel maintains regulated current drive using internal DAC control and loop feedback measurement, enabling simultaneous analog control signal transmission and HART digital communication.\u003c\/p\u003e\n\u003cp\u003eChannel-level diagnostics support open circuit detection and discrepancy monitoring between commanded and readback current values. The output stage is designed for field instrumentation interfacing where loop impedance, compliance voltage, and signal integrity are constrained by 800 ohm maximum load and 16 V compliance limit.\u003c\/p\u003e\n\u003cp\u003eHART modem integration allows bidirectional communication for field device configuration, process variable access, and instrument diagnostics without interrupting analog control current.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CC-PAOH01 support per-channel fail-safe configuration?\u003cbr\u003eA: Yes. Each channel supports FAILOPT configuration with HOLD LAST VALUE or SHED TO SAFE VALUE behavior. In hardware failure conditions, outputs transition to zero state.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum load supported per output channel?\u003cbr\u003eA: Each channel supports up to 800 ohm resistive load, constrained by 16 V maximum output compliance voltage.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swap supported during module operation?\u003cbr\u003eA: Hot insertion\/removal is dependent on Series C I\/O rack implementation. Field wiring should remain de-energized unless system architecture explicitly supports live replacement procedures.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe module shall be installed in a Series C I\/O chassis slot with verified backplane seating to ensure stable 24 VDC distribution and communication integrity. Field wiring for 4-20 mA loops must be routed using shielded twisted pair conductors with single-point grounding of the shield at the cabinet earth reference.\u003c\/p\u003e\n\u003cp\u003eLoop resistance must be calculated to ensure total load remains within compliance voltage limits under worst-case field device conditions. Terminal tightening must follow manufacturer torque specifications for spring-clamp or screw-type termination blocks.\u003c\/p\u003e\n\u003cp\u003eHART communication performance depends on maintaining proper loop impedance stability and avoiding excessive capacitance across long cable runs. Separation from high-voltage switching conductors is required to prevent induced noise on analog current loops.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44301393592408,"sku":"CC-PAOH01 51405039-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CC-PAOH0151405039-175-3.jpg?v=1782892905","url":"https:\/\/www.industriaxplc.com\/products\/honeywell-cc-paoh01-51405039-175-analog-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}