{"product_id":"honeywell-cc-paim01-low-level-analog-mux-module","title":"Honeywell CC-PAIM01 Low-Level Analog MUX Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-PAIM01 is a specialized low-level analog multiplexing module engineered for the precise acquisition of millivolt-level signals, including thermocouple and RTD inputs. As a critical component in process control environments, this module performs channel selection and signal conditioning for low-amplitude analog inputs, ensuring high measurement integrity in temperature-sensitive instrumentation loops. It is widely utilized in refinery, power generation, and chemical processing applications where stable signal routing is required to minimize measurement drift and operational downtime.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow-noise analog multiplexer architecture optimized for thermocouple and RTD signal processing.\u003c\/li\u003e\n\u003cli\u003eBandwidth-limited design (0 to 4.7 Hz at -3 dB) to effectively filter electrical noise and enhance signal stability.\u003c\/li\u003e\n\u003cli\u003eHigh-precision measurement path designed to minimize gain drift and temperature-induced deviations.\u003c\/li\u003e\n\u003cli\u003eSupports millivolt-level thermocouple inputs and high-level diagnostic inputs within defined operational limits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe CC-PAIM01 is designed for integration into industrial control systems requiring high-sensitivity analog data acquisition. Typical applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature monitoring systems using thermocouples or RTDs.\u003c\/li\u003e\n\u003cli\u003eHigh-sensitivity process instrumentation loops.\u003c\/li\u003e\n\u003cli\u003eIndustrial automation systems in power plants and chemical processing facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-PAIM01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eLow-Level Analog MUX Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Bandwidth\u003c\/td\u003e\n\u003ctd\u003e0 to 4.7 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Range (TC)\u003c\/td\u003e\n\u003ctd\u003e-20 to 100 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Input (TC Mode)\u003c\/td\u003e\n\u003ctd\u003e-10 to 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Input (RTD Mode)\u003c\/td\u003e\n\u003ctd\u003e-1 to 2 V at 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGain Error\u003c\/td\u003e\n\u003ctd\u003e0.050% Full Scale (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Stability\u003c\/td\u003e\n\u003ctd\u003e20 ppm per deg C (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong Term Drift\u003c\/td\u003e\n\u003ctd\u003e500 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the system power is completely disconnected before inserting or removing the module from the rack.\u003c\/li\u003e\n\u003cli\u003eHandle the module using proper ESD (Electrostatic Discharge) precautions to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003cli\u003eEnsure the module is fully seated in the designated slot to maintain reliable backplane communication.\u003c\/li\u003e\n\u003cli\u003eRoute signal cables away from high-voltage or high-EMI sources to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eVerify that the operating environment remains within the specified temperature range (0 to 60 deg C) to ensure optimal performance and longevity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the CC-PAIM01?\u003c\/strong\u003e\u003cbr\u003eThe CC-PAIM01 is a multiplexer module used to acquire and condition low-level analog signals, such as those from thermocouples, for use in Honeywell process control systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module handle high-voltage inputs?\u003c\/strong\u003e\u003cbr\u003eNo, this module is designed for low-level signals. While it has specified maximum continuous input limits for diagnostic purposes, it is not intended for high-voltage power measurement.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44664319639640,"sku":"CC-PAIM01","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/wm_1_ecd0bd9b-fc16-4ff2-8d83-b2c43016590f.jpg?v=1787774062","url":"https:\/\/www.industriaxplc.com\/products\/honeywell-cc-paim01-low-level-analog-mux-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}