{"product_id":"honeywell-900r08r-0200-controledge-hc900-8-slot-i-o-rack","title":"Honeywell 900R08R-0200 ControlEdge HC900 8-Slot I\/O Rack","description":"\u003ch2\u003eHoneywell 900R08R-0200 ControlEdge HC900 8-Slot I\/O Rack\u003c\/h2\u003e\n\u003cp\u003eConfigured for modular I\/O expansion and redundant power distribution in the Honeywell ControlEdge HC900 system, the \u003cstrong\u003eHoneywell 900R08R-0200\u003c\/strong\u003e (\u003cstrong\u003e900R08R-0200\u003c\/strong\u003e 8-Slot I\/O Rack) provides the physical backplane interface for controller and I\/O module installation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900R08R-0200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e8-Slot I\/O and Controller Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eControlEdge HC900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Capacity\u003c\/td\u003e\n\u003ctd\u003e8 I\/O module slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Support\u003c\/td\u003e\n\u003ctd\u003eDual redundant power supply configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot-Swap Function\u003c\/td\u003e\n\u003ctd\u003eSupports live insertion and removal of compatible I\/O modules under system power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e137 mm H x 530.9 mm W x 151.7 mm D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 4422 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane dependent; determined by installed modules and power supply configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eConformal coating, G3 harsh environment compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, ATEX \/ FM Class 1 Div 2 (system dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Rack Integration and Signal Isolation\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 900R08R-0200 provides the mechanical backplane structure for ControlEdge HC900 controller and I\/O module assemblies. Therefore, it maintains the electrical connection between installed modules and the internal system bus.\u003c\/p\u003e\n\u003cp\u003eThe rack design supports process control module installation where analog and digital field signals require controlled routing. In addition, compatible Honeywell modules can implement features such as 4-20 mA HART loop protocol handling, FOUNDATION Fieldbus \/ Profibus PA connectivity, and channel-to-channel isolation at the module level.\u003c\/p\u003e\n\u003cp\u003eThe rack itself does not perform signal conversion or protocol processing. Instead, it supplies the physical mounting and interconnection platform required by installed control modules.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 900R08R-0200 support redundant power supply operation?\u003cbr\u003eA: Yes. The rack supports dual redundant power supply configurations when used with compatible ControlEdge HC900 power modules.\u003c\/p\u003e\n\u003cp\u003eQ: Can I\/O modules be replaced while the rack remains powered?\u003cbr\u003eA: The rack supports hot-swap installation and removal of compatible I\/O modules. Replacement procedures must follow Honeywell system maintenance instructions.\u003c\/p\u003e\n\u003cp\u003eQ: Does the rack provide analog signal isolation or HART communication processing?\u003cbr\u003eA: No. The rack provides mechanical mounting and backplane interconnection. Signal isolation and communication functions depend on the installed I\/O modules.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 900R08R-0200 on a stable control cabinet mounting surface with sufficient clearance for module insertion and wiring access.\u003c\/p\u003e\n\u003cp\u003eVerify that the rack backplane connectors remain free from dust, moisture, and mechanical contamination before module installation.\u003c\/p\u003e\n\u003cp\u003eRoute field wiring separately from high-voltage power conductors to reduce electrical interference. Maintain proper cable shielding and connect shield layers according to the grounding requirements of the installed ControlEdge HC900 modules.\u003c\/p\u003e\n\u003cp\u003eBefore applying system power, confirm the correct placement of controller modules, I\/O modules, and redundant power components. Check all module seating positions to ensure proper backplane engagement.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44503142596696,"sku":"900R08R-0200","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/900R08R-0200-3_1200x1200_ddd06739-50e8-49e5-a356-838c7983e7d8.jpg?v=1785921127","url":"https:\/\/www.industriaxplc.com\/products\/honeywell-900r08r-0200-controledge-hc900-8-slot-i-o-rack","provider":"IndustriaX Limited","version":"1.0","type":"link"}