{"product_id":"honeywell-900a16-0103-high-level-analog-input-module","title":"Honeywell 900A16-0103 High Level Analog Input Module","description":"\u003ch2\u003eHoneywell 900A16-0103 High Level Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for isolated analog signal acquisition in the Honeywell ControlEdge HC900 platform, the \u003cstrong\u003eHoneywell 900A16-0103\u003c\/strong\u003e (\u003cstrong\u003e900A16-0103\u003c\/strong\u003e High Level Analog Input Module) provides direct electrical conversion of voltage and current field inputs through a 16-channel analog interface.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900A16-0103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHigh Level Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eControlEdge HC900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e13.4 x 3.3 x 5.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e75 mA maximum at 5 VDC; 50 mA maximum at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs per Module\u003c\/td\u003e\n\u003ctd\u003e16 isolated inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003eVoltage (V), Current (mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e+\/- 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003eGreater than 1 megohm for voltage inputs; 250 ohms for current inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Input Isolation\u003c\/td\u003e\n\u003ctd\u003e400 VDC point to point; 1 kVDC to logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Consumption\u003c\/td\u003e\n\u003ctd\u003e2 uA maximum per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Converter\u003c\/td\u003e\n\u003ctd\u003eOne converter per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Resolution\u003c\/td\u003e\n\u003ctd\u003e15 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-range Limit\u003c\/td\u003e\n\u003ctd\u003e+\/- 10% for linear voltage ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Effect on Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.01% of full scale per deg C maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong Term Stability\u003c\/td\u003e\n\u003ctd\u003e0.1% per year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlace of Shipment\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHoneywell Process Analog Signal Isolation and Conversion\u003c\/h3\u003e\n\u003cp\u003eThe 900A16-0103 uses isolated analog input channels to acquire field voltage and current signals within the ControlEdge HC900 architecture. Each channel maintains electrical separation through galvanic isolation, which reduces signal interference between field devices and controller logic circuits.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the module supports standard process instrumentation interfaces that commonly operate with 4-20 mA current loops. The isolated channel design supports channel-to-channel isolation requirements in distributed control applications where multiple field transmitters connect to a single I\/O assembly.\u003c\/p\u003e\n\u003cp\u003eThe module performs analog-to-digital conversion through a dedicated 15-bit A\/D converter. Therefore, the controller receives updated process values at a fixed 100 ms update interval for execution in configured control strategies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the Honeywell 900A16-0103 provide isolation between field inputs and controller logic?\u003cbr\u003eA: Yes. The module provides 400 VDC point-to-point galvanic isolation and 1 kVDC isolation between input circuits and logic.\u003c\/p\u003e\n\u003cp\u003eQ: What analog signals can the 900A16-0103 measure?\u003cbr\u003eA: The module accepts voltage and current input signals through 16 isolated analog input channels.\u003c\/p\u003e\n\u003cp\u003eQ: What is the A\/D conversion capability of the 900A16-0103 module?\u003cbr\u003eA: The module uses one A\/D converter with 15-bit resolution and a 100 ms update rate.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the Honeywell 900A16-0103 module into the designated ControlEdge HC900 rack position according to the system hardware configuration.\u003c\/p\u003e\n\u003cp\u003eConnect field analog wiring using shielded instrumentation cable where required by the application. Terminate cable shields according to the plant grounding practice to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eSeparate analog signal wiring from high-voltage power conductors and switching circuits. Verify input polarity before applying field signals to prevent incorrect process value readings.\u003c\/p\u003e\n\u003cp\u003eConfirm that the connected transmitters or devices match the configured voltage or current input type. After installation, check channel status and measured values through the controller configuration software.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44503235100760,"sku":"900A16-0103","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/900A16-0103-3_1200x1200_836ebc7a-2beb-4345-bcef-ec473b3cb1d8.jpg?v=1785922486","url":"https:\/\/www.industriaxplc.com\/products\/honeywell-900a16-0103-high-level-analog-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}