{"product_id":"honeywell-900a01-0102-universal-analog-input-module","title":"Honeywell 900A01-0102 Universal Analog Input Module","description":"\u003ch2\u003eHoneywell 900A01-0102 Universal Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for universal analog signal acquisition in the Honeywell HC900 \/ ControlEdge HC900 system, the \u003cstrong\u003eHoneywell 900A01-0102\u003c\/strong\u003e (\u003cstrong\u003e900A01-0102\u003c\/strong\u003e Universal Analog Input Module) provides direct physical and electrical processing of field temperature, voltage, current, and resistance signals.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900A01-0102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eUniversal Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell HC900 \/ ControlEdge HC900 Process Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 universal analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Signals\u003c\/td\u003e\n\u003ctd\u003eThermocouple, RTD, voltage, millivolt, current, resistance, slidewire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC with signal conditioning support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Range\u003c\/td\u003e\n\u003ctd\u003e0-10 VDC, 0-5 VDC, 1-5 VDC, +\/-10 VDC, millivolt ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Support\u003c\/td\u003e\n\u003ctd\u003ePt100, Pt200, Pt500, Pt1000, Ni120, Cu10 and related sensor types\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Support\u003c\/td\u003e\n\u003ctd\u003eTypes B, E, J, K, N, R, S, T and other supported thermocouple inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel isolation and backplane isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Method\u003c\/td\u003e\n\u003ctd\u003eDigital conversion synchronized with controller execution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eChannel status monitoring, sensor fault indication, configuration diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e10% to 90% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 137 mm H x 35.6 mm W x 152 mm D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEstimated Shipping Size\u003c\/td\u003e\n\u003ctd\u003e13.2 x 14.2 x 3.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupplied from HC900 controller rack backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Signal Conditioning and Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 900A01-0102 processes multiple field signal types through configurable input channels. Each channel supports independent engineering configuration for sensor selection, scaling, and alarm handling.\u003c\/p\u003e\n\u003cp\u003eThe module applies channel-to-channel isolation to reduce signal interference between field devices. In addition, the input design supports cold junction compensation (CJC) for thermocouple measurements and maintains measurement accuracy during temperature changes at the terminal connection point.\u003c\/p\u003e\n\u003cp\u003eFor process instrumentation loops, the module can interface with 4-20 mA HART signal sources through suitable external signal conditioning arrangements. It also supports integration with FOUNDATION Fieldbus and Profibus PA based field architectures when used with compatible Honeywell system interfaces.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 900A01-0102 accept different input types on separate channels?\u003cbr\u003eA: Yes. Each of the 8 channels can be configured independently for supported thermocouple, RTD, voltage, current, resistance, or millivolt input types.\u003c\/p\u003e\n\u003cp\u003eQ: Does the 900A01-0102 provide electrical isolation between input channels?\u003cbr\u003eA: Yes. The module provides channel-to-channel isolation and backplane isolation to limit interference between field signals and controller electronics.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support hot-swap replacement?\u003cbr\u003eA: The module replacement procedure depends on the HC900 rack configuration and system operating conditions. Field replacement should follow the applicable Honeywell hardware installation procedure.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in the designated Honeywell HC900 controller rack position.\u003c\/li\u003e\n\u003cli\u003eVerify rack power isolation before removing or inserting the module.\u003c\/li\u003e\n\u003cli\u003eConnect field wiring according to the configured input type and terminal assignment.\u003c\/li\u003e\n\u003cli\u003eUse shielded cables for low-level analog signals such as thermocouple and millivolt inputs.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the plant grounding standard to reduce electrical noise.\u003c\/li\u003e\n\u003cli\u003eSeparate analog signal wiring from high-current power cables and switching circuits.\u003c\/li\u003e\n\u003cli\u003eConfirm channel configuration parameters before placing the controller into normal operation.\u003c\/li\u003e\n\u003cli\u003eCheck diagnostic indicators after installation to verify module status and field signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44497875730520,"sku":"900A01-0102","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/900A01-0102-3_1200x1200_e21194ff-cd35-4e49-bdf1-046a3eaeb853.jpg?v=1785831163","url":"https:\/\/www.industriaxplc.com\/products\/honeywell-900a01-0102-universal-analog-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}