{"product_id":"honeywell-8c-taim01-analog-input-module","title":"Honeywell 8C-TAIM01 Analog Input Module","description":"\u003ch2\u003eHoneywell 8C-TAIM01 Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for thermocouple and RTD signal acquisition in the Honeywell Experion PKS Series 8 I\/O system, the \u003cstrong\u003eHoneywell 8C-TAIM01 51306999-175\u003c\/strong\u003e (\u003cstrong\u003e8C-TAIM01\u003c\/strong\u003e Analog Input Module) provides direct physical signal conversion and isolated measurement execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-TAIM01 51306999-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS Series 8 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.24 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e14.5 x 12 x 5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eThermocouple and \/ or RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e64 fully-isolated channel-to-channel inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Scan Rate\u003c\/td\u003e\n\u003ctd\u003e1 Second fixed by IOM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Bandwidth\u003c\/td\u003e\n\u003ctd\u003e0 to 4.7 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Range\u003c\/td\u003e\n\u003ctd\u003e-20 to +100 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Stability\u003c\/td\u003e\n\u003ctd\u003e+\/-20 ppm per deg C max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong Term Drift\u003c\/td\u003e\n\u003ctd\u003e500 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Type\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel electrical isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation and Process Signal Handling\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 8C-TAIM01 51306999-175 processes thermocouple and RTD field signals through 64 fully-isolated input channels. Therefore, each measurement channel maintains electrical separation from adjacent inputs to reduce field wiring interference.\u003c\/p\u003e\n\u003cp\u003eThe module supports temperature measurement applications where cold junction compensation (CJC) and sensor linearization functions are managed through the Series 8 I\/O processing architecture. Additionally, the input bandwidth of 0 to 4.7 Hz (-3 dB) defines the signal response range for temperature-related process variables.\u003c\/p\u003e\n\u003cp\u003eUnlike current loop input modules designed for 4-20 mA HART signals, this module directly accepts millivolt-level thermocouple signals and resistance-based RTD measurements. Consequently, sensor type selection and field termination configuration determine the final measurement behavior.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What field signals does the 8C-TAIM01 51306999-175 accept?\u003cbr\u003eA: The module accepts thermocouple and RTD input signals through 64 fully-isolated channels. It supports a nominal input range of -20 to +100 mV.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module provide channel-to-channel isolation?\u003cbr\u003eA: Yes. The 8C-TAIM01 provides fully-isolated channel-to-channel inputs, which separates individual measurement circuits and reduces electrical coupling between field signals.\u003c\/p\u003e\n\u003cp\u003eQ: What is the fixed input scan rate of this module?\u003cbr\u003eA: The input scan rate is 1 Second and is fixed by the associated Series 8 I\/O Module (IOM) processing architecture.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 8C-TAIM01 51306999-175 module in the designated Honeywell Series 8 I\/O mounting assembly according to the system hardware configuration requirements.\u003c\/p\u003e\n\u003cp\u003eUse shielded field wiring for thermocouple and RTD connections where the installation environment contains electrical noise sources. Connect cable shields according to the site grounding standard and avoid parallel routing with high-current power conductors.\u003c\/p\u003e\n\u003cp\u003eVerify correct sensor wiring polarity before energizing the I\/O assembly. Thermocouple connections require correct lead identification because reversed polarity affects temperature measurement direction. RTD wiring should maintain consistent conductor routing to minimize resistance measurement errors.\u003c\/p\u003e\n\u003cp\u003eConfirm that field terminals, I\/O connectors, and module seating are mechanically secure before system commissioning. Perform channel verification through the Experion PKS engineering tools after installation.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44416286621784,"sku":"51306999-175 8C-TAIM01 8U-TAIM01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/51306999-1758C-TAIM018U-TAIM01-3.jpg?v=1784714713","url":"https:\/\/www.industriaxplc.com\/products\/honeywell-8c-taim01-analog-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}