{"product_id":"honeywell-51402455-100-ucn-interface-module","title":"Honeywell 51402455-100 UCN Interface Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 51402455-100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUniversal Control Network interface module is engineered to provide a stable communication pathway between High-Performance Process Manager (HPM) controllers and the Universal Control Network (UCN) used in distributed control architectures. Installed within the HPM chassis, this module manages network-level data exchange and ensures reliable coordination between control processors, I\/O subsystems, and supervisory nodes.\u003c\/p\u003e\n\u003cp\u003eDesigned for use in Honeywell’s TDC 3000 and hybrid Experion environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51402455-100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule supports deterministic communication required for real-time industrial process control. It incorporates a dedicated communication processor and onboard memory resources to manage network traffic, buffering, and protocol handling.\u003c\/p\u003e\n\u003cp\u003eThe module is typically deployed alongside communication control cards and I\/O link modules in the HPM rack, allowing the controller to interact with other UCN nodes including operator stations, application modules, and remote I\/O systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e51402455-100\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eUniversal Control Network Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eCommunication interface between HPM controller and UCN network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd\u003eHoneywell High-Performance Process Manager (HPM), TDC 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eUCN driver\/receiver interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessing Hardware\u003c\/td\u003e\n\u003ctd\u003eEmbedded communication processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eIntegrated SRAM for buffering and protocol management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirement\u003c\/td\u003e\n\u003ctd\u003e+5 VDC supplied by HPM chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Type\u003c\/td\u003e\n\u003ctd\u003eSlot-mounted module within HPM rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Format\u003c\/td\u003e\n\u003ctd\u003eStandard HPM control card form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Manufacture\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Condition\u003c\/td\u003e\n\u003ctd\u003eFactory-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Functional Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eReliable Network Connectivity\u003cbr\u003eProvides deterministic communication between the HPM controller and other nodes connected through the Universal Control Network.\u003c\/p\u003e\n\u003cp\u003eIntegrated Communication Processing\u003cbr\u003eA dedicated processor manages protocol handling and message routing to maintain stable data transfer across distributed system components.\u003c\/p\u003e\n\u003cp\u003eOptimized for TDC 3000 Architecture\u003cbr\u003eFully compatible with Honeywell’s legacy distributed control framework and commonly used in hybrid migrations toward Experion PKS.\u003c\/p\u003e\n\u003cp\u003eCompact HPM Form Factor\u003cbr\u003eDesigned to fit standard HPM card slots, simplifying installation and maintenance within existing control cabinets.\u003c\/p\u003e\n\u003cp\u003eIndustrial Compliance\u003cbr\u003eCertified for industrial environments through CE, UL, and CSA approvals.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51402455-100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einterface module is commonly used in industrial control environments where Honeywell distributed control systems are deployed.\u003c\/p\u003e\n\u003cp\u003eTypical installations include:\u003c\/p\u003e\n\u003cp\u003e• Oil and gas processing facilities\u003cbr\u003e• Petrochemical and refinery plants\u003cbr\u003e• Power generation control systems\u003cbr\u003e• Chemical production plants\u003cbr\u003e• Large-scale process manufacturing environments\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis module must be installed in an HPM chassis equipped with compatible communication and I\/O link cards. Proper system configuration is required to enable UCN connectivity and ensure correct node addressing within the control network.\u003c\/p\u003e\n\u003cp\u003eEnvironmental conditions should comply with the operational specifications of Honeywell control racks, including appropriate temperature control and enclosure protection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary role of the 51402455-100 module?\u003c\/strong\u003e\u003cbr\u003eIt enables communication between the HPM controller and the Universal Control Network, allowing distributed nodes within the control system to exchange operational data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module be used with Experion PKS systems?\u003c\/strong\u003e\u003cbr\u003eYes. It is typically used in hybrid installations where TDC 3000 components remain connected to newer Experion infrastructure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere is the module installed?\u003c\/strong\u003e\u003cbr\u003eThe card is installed inside the HPM rack or chassis alongside other communication and control modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module include its own power supply?\u003c\/strong\u003e\u003cbr\u003eNo. Power is provided through the HPM chassis backplane, typically +5 VDC.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43852938444888,"sku":"51402455-100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/51402455-1002.jpg?v=1773302681","url":"https:\/\/www.industriaxplc.com\/products\/honeywell-51402455-100-ucn-interface-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}