{"product_id":"honeywell-51402089-100-enhanced-peripheral-display-generator","title":"Honeywell 51402089-100 Enhanced Peripheral Display Generator","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51402089-100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnhanced Peripheral Display Generator (EPDG2) interface board is designed for operator workstation nodes used in the Honeywell TDC 3000 distributed control architecture. This board acts as the hardware interface responsible for generating video output and managing multiple operator peripherals including keyboards, pointing devices, and printers.\u003c\/p\u003e\n\u003cp\u003eInstalled within Universal Station nodes,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51402089-100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegrates display signal generation with peripheral communication, enabling reliable interaction between the operator console and the control system. Compared with earlier EPDG hardware generations, EPDG2 improves peripheral compatibility and provides extended support for CE-compliant I\/O paddle boards.\u003c\/p\u003e\n\u003cp\u003eThe module is engineered for continuous operation in industrial control environments and supports various legacy operator interface devices used in TDC 3000 console furniture.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e51402089-100\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEnhanced Peripheral Display Generator (EPDG2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eHoneywell TDC 3000 Universal Station\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eVideo signal generation and peripheral communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003eRS-485, Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeripheral Support\u003c\/td\u003e\n\u003ctd\u003eKeyboard, mouse, trackball, touchscreen, printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Device Support\u003c\/td\u003e\n\u003ctd\u003eSCSI interface for Bernoulli and Zip drives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e−20 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e−40 °C to +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e0–95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eUL, CE, FCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturing Standards\u003c\/td\u003e\n\u003ctd\u003eISO 9001, ISO 14001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51402089-100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eboard operates in conjunction with dedicated I\/O paddle boards mounted on the rear transition assembly. Selection depends on regulatory compliance requirements.\u003c\/p\u003e\n\u003cp\u003eCompatible paddle board options include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEPDGP (Non-CE) – 51404584-100\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEPDGC-1 (CE compliant) – 51402447-100\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEPDGC-2 (CE compliant) – 51402447-200\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese transition boards provide the external connections for display signals, keyboard interface, pointing devices, and printer ports.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Functional Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eDisplay Signal Generation\u003cbr\u003eThe module produces video signals used by Universal Station operator displays, supporting stable graphical interface output within TDC 3000 consoles.\u003c\/p\u003e\n\u003cp\u003ePeripheral Device Management\u003cbr\u003eIntegrated controllers manage communication with keyboards, trackballs, mice, and touchscreen devices used by plant operators.\u003c\/p\u003e\n\u003cp\u003eLegacy Storage Interface\u003cbr\u003eSCSI support allows connection of removable storage devices such as Bernoulli and Zip drives historically used in Honeywell operator stations.\u003c\/p\u003e\n\u003cp\u003ePrinter Connectivity\u003cbr\u003eDedicated interface support enables report and alarm printing directly from operator stations.\u003c\/p\u003e\n\u003cp\u003eImproved Hardware Compatibility\u003cbr\u003eAs a second-generation EPDG design, it offers broader compatibility with later-revision Universal Station hardware and CE-certified I\/O boards.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eProcess control operator consoles in Honeywell TDC 3000 systems\u003cbr\u003eRefurbishment or maintenance of Universal Station workstations\u003cbr\u003eReplacement of first-generation EPDG display interface boards\u003cbr\u003eLegacy system upgrades requiring CE-compliant interface support\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which systems use the 51402089-100 interface board?\u003c\/strong\u003e\u003cbr\u003eIt is designed specifically for Universal Station nodes in Honeywell TDC 3000 distributed control systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this board replace the earlier EPDG module?\u003c\/strong\u003e\u003cbr\u003eYes. In most Universal Station configurations, EPDG2 serves as a functional upgrade for earlier EPDG hardware, provided the correct paddle board is installed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this board compatible with Honeywell Experion systems?\u003c\/strong\u003e\u003cbr\u003eNo. The module was designed for the TDC 3000 platform and is not intended for modern Experion PKS architectures.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43852730138712,"sku":"51402089-100","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/51402089-1002.jpg?v=1773301633","url":"https:\/\/www.industriaxplc.com\/products\/honeywell-51402089-100-enhanced-peripheral-display-generator","provider":"IndustriaX Limited","version":"1.0","type":"link"}