{"product_id":"ge-multilin-ur6rh-ur-6rh-digital-input-output-module","title":"GE Multilin UR6RH UR-6RH Digital Input\/Output Module","description":"\u003ch2\u003eGE Multilin UR6RH UR-6RH Digital Input\/Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for contact signal acquisition and relay command execution in GE Multilin Universal Relay (UR) platforms, the \u003cstrong\u003eGE Multilin UR-6RH\u003c\/strong\u003e (\u003cstrong\u003eUR-6RH\u003c\/strong\u003e Digital Input\/Output Module) provides direct physical\/electrical execution between substation field devices and protection relay logic.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUR-6RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard UR chassis slide-in PCB module form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Contact Input \/ Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform\u003c\/td\u003e\n\u003ctd\u003eUniversal Relay (UR) \/ UR Plus Modular Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 opto-isolated contact inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e6 relay contact outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Configuration\u003c\/td\u003e\n\u003ctd\u003e2 Form-A outputs, 4 Form-C outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Options\u003c\/td\u003e\n\u003ctd\u003e24 V, 48 V, 110 V, 125 V, or 250 VDC ordering options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm-A Operate Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 4 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output Current\u003c\/td\u003e\n\u003ctd\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMake and Carry Rating\u003c\/td\u003e\n\u003ctd\u003e30 A for 0.2 s per ANSI\/IEEE C37.90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGE UR Modular I\/O Architecture and Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe UR-6RH module operates as a slide-in expansion card within GE Multilin Universal Relay chassis configurations. The module extends relay hardware capacity through dedicated digital contact acquisition and programmable output switching channels.\u003c\/p\u003e\n\u003cp\u003eThe module supports deterministic relay control execution through the UR platform backplane interface. The firmware configuration is managed through EnerVista UR Setup Software, allowing assignment of contact inputs and relay outputs according to protection and automation logic requirements.\u003c\/p\u003e\n\u003cp\u003eThe module is designed for industrial control applications requiring direct connection to circuit breakers, disconnect switches, alarms, control switches, and auxiliary relay contacts.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the UR-6RH support isolated digital input channels?\u003cbr\u003eA: Yes. The digital input channels use opto-isolation to provide electrical separation from connected field contact circuits and improve transient noise immunity.\u003c\/p\u003e\n\u003cp\u003eQ: What type of output contacts are provided by the UR-6RH?\u003cbr\u003eA: The module provides two Form-A normally open outputs and four Form-C changeover outputs with normally open, normally closed, and common terminals.\u003c\/p\u003e\n\u003cp\u003eQ: Is the UR-6RH designed for standalone operation?\u003cbr\u003eA: No. The UR-6RH is a modular expansion card intended for installation in compatible GE Multilin Universal Relay chassis systems.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the UR-6RH module only in compatible GE Multilin UR Series chassis slots.\u003c\/li\u003e\n\u003cli\u003eVerify the ordering option matches the required substation DC control voltage before field connection.\u003c\/li\u003e\n\u003cli\u003eUse shielded wiring practices for control circuits installed in high electromagnetic interference environments.\u003c\/li\u003e\n\u003cli\u003eTerminate cable shields according to the site grounding standard and avoid creating multiple unintended ground paths.\u003c\/li\u003e\n\u003cli\u003eSeparate low-level signal wiring from high-energy breaker control and power conductors.\u003c\/li\u003e\n\u003cli\u003eConfirm terminal assignments for Form-A and Form-C output contacts before connecting external control circuits.\u003c\/li\u003e\n\u003cli\u003ePerform contact input verification and output relay operation testing after module installation using the configured UR relay logic.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44497884643416,"sku":"UR6RH","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/UR6LV_d1516130-6c1e-42e8-8eef-4d83c14350a0.jpg?v=1785831700","url":"https:\/\/www.industriaxplc.com\/products\/ge-multilin-ur6rh-ur-6rh-digital-input-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}