{"product_id":"ge-multilin-369-hi-r-m-0-0-0-motor-management-relay","title":"GE Multilin 369-HI-R-M-0-0-0 Motor Management Relay","description":"\u003ch2\u003eGE Multilin 369-HI-R-M-0-0-0 Motor Management Relay\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Multilin 369-HI-R-M-0-0-0\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e369\u003c\/strong\u003e Motor Management Relay, operates as a dedicated hardware component for motor protection, thermal monitoring, and electrical measurement within GE Multilin motor protection platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e369-HI-R-M-0-0-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e29.6 cm x 10.7 cm x 20.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eDigital Microprocessor-Based Motor Management Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Power\u003c\/td\u003e\n\u003ctd\u003e50-300 VDC \/ 60-265 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Inputs\u003c\/td\u003e\n\u003ctd\u003e1 A or 5 A secondary CT inputs, field configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Inputs\u003c\/td\u003e\n\u003ctd\u003eUp to 280 VAC phase line voltage via metering option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Inputs\u003c\/td\u003e\n\u003ctd\u003e12 programmable RTD inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e6 optically isolated assignable inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e4 configurable outputs, 0-1 mA, 0-20 mA, or 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS232 front port and RS485 rear port with Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eStandard panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGE Multilin Motor Thermal and Power Monitoring Functions\u003c\/h3\u003e\n\u003cp\u003eThe 369-HI-R-M-0-0-0 integrates motor protection algorithms with thermal measurement and power metering functions. The 12-channel RTD package provides direct temperature acquisition for stator windings, bearings, and ambient monitoring. The motor thermal model supports ANSI 49 protection behavior, while current and voltage measurement channels provide monitoring of operating electrical conditions.\u003c\/p\u003e\n\u003cp\u003eThe integrated metering option provides measurement of kW, kVA, kvar, power factor, kWh, frequency, and additional analog output assignment. Analog channels can be configured for process monitoring or connection to external control systems.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 369-HI-R-M-0-0-0 support hot-swap replacement during operation?\u003cbr\u003eA: The relay is designed for panel mounting and fixed wiring installation. Hot-swap operation is not specified for this hardware configuration.\u003c\/p\u003e\n\u003cp\u003eQ: Which communication protocol is available through the rear communication port?\u003cbr\u003eA: The rear RS485 port supports Modbus RTU communication for connection to supervisory or control systems.\u003c\/p\u003e\n\u003cp\u003eQ: How are RTD inputs used in the relay application?\u003cbr\u003eA: The 12 programmable RTD inputs acquire motor thermal signals from sensors such as platinum, nickel, and copper resistance temperature devices for temperature-based protection functions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the GE Multilin 369-HI-R-M-0-0-0 in a suitable panel enclosure with adequate clearance for wiring access and heat dissipation. Connect CT secondary wiring according to the required phase and ground current measurement configuration.\u003c\/p\u003e\n\u003cp\u003eUse shielded cables for low-level analog and communication wiring where required. Terminate cable shields according to site grounding practices to reduce electrical noise coupling. Separate communication, RTD, and analog signal wiring from high-current motor feeder conductors.\u003c\/p\u003e\n\u003cp\u003eVerify control power compatibility before energizing the relay. Confirm CT polarity, VT connections, RTD channel assignments, and communication parameters during commissioning. Firmware compatibility should be checked before performing any configuration or maintenance procedure.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44511732793432,"sku":"369-HI-R-M-0-0-0","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/369-HI-R-M-0-0-0-H-E.jpg?v=1785923789","url":"https:\/\/www.industriaxplc.com\/products\/ge-multilin-369-hi-r-m-0-0-0-motor-management-relay","provider":"IndustriaX Limited","version":"1.0","type":"link"}