{"product_id":"ge-multilin-369-hi-r-0-0-0-0-e-motor-protection-relay","title":"GE Multilin 369-HI-R-0-0-0-0-E Motor Protection Relay","description":"\u003ch2\u003eGE Multilin 369-HI-R-0-0-0-0-E Motor Protection Relay\u003c\/h2\u003e\n\u003cp\u003eConfigured for three-phase motor protection, monitoring, and trip control in industrial motor management systems, the \u003cstrong\u003eGE Multilin 369-HI-R-0-0-0-0-E\u003c\/strong\u003e (\u003cstrong\u003e369\u003c\/strong\u003e Motor Protection Relay) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e369-HI-R-0-0-0-0-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric Multilin product family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e11 cm W x 30 cm H x 21 cm L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal 10 W, maximum 20 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Motor Protection Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e369 Motor Management Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Power Supply\u003c\/td\u003e\n\u003ctd\u003e50-300 VDC, 60-265 VAC, 48-62 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Current Input\u003c\/td\u003e\n\u003ctd\u003e1 A and 5 A secondary CT inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Current Input Frequency\u003c\/td\u003e\n\u003ctd\u003e20 to 100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485 Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Inputs\u003c\/td\u003e\n\u003ctd\u003e3-wire RTD inputs for 100 ohm platinum, 100 ohm nickel, 120 ohm nickel, and 10 ohm copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Relays\u003c\/td\u003e\n\u003ctd\u003e4 configurable relays for trip, auxiliary, and alarm functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal Coating\u003c\/td\u003e\n\u003ctd\u003eEnvironmental option E coating for industrial environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe GE Multilin 369 series uses microprocessor-based processing for motor protection calculations, event recording, metering, and relay control functions. The relay supports RS485 Modbus RTU communication for integration with industrial control networks.\u003c\/p\u003e\n\u003cp\u003eThe unit provides deterministic relay operation through embedded protection firmware, including thermal overload modeling, phase current analysis, ground fault detection, locked rotor protection, mechanical jam detection, and undercurrent monitoring. Firmware operation supports configuration storage, self-testing routines, and recorded trip information.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 369-HI-R-0-0-0-0-E support hot-swap replacement during operation?\u003cbr\u003eA: The relay is designed as a panel-mounted protection device. Replacement procedures require isolation of control power, current inputs, and field wiring before removal.\u003c\/p\u003e\n\u003cp\u003eQ: What current transformer inputs are supported by this relay?\u003cbr\u003eA: The relay accepts phase current transformer inputs rated for 1 A or 5 A secondary values with software selection.\u003c\/p\u003e\n\u003cp\u003eQ: Which communication protocol is available through the rear communication port?\u003cbr\u003eA: The relay provides an RS485 serial interface supporting Modbus RTU communication.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the relay in a suitable protective enclosure with access for control wiring, CT wiring, communication connections, and operator interface access.\u003c\/p\u003e\n\u003cp\u003eMaintain separation between CT signal wiring, digital input wiring, and high voltage conductors to reduce electrical interference. Apply shield grounding practices according to the installation environment and system grounding requirements.\u003c\/p\u003e\n\u003cp\u003eVerify CT polarity, phase sequence, and grounding connections before commissioning. Confirm control voltage compatibility with the selected HI power supply range before energizing the relay.\u003c\/p\u003e\n\u003cp\u003eRTD wiring should use appropriate three-wire connection methods and avoid routing alongside high-current motor feeder cables. Configure protection parameters according to motor nameplate data and application requirements before placing the relay into service.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44511702679640,"sku":"369-HI-R-0-0-0-0-E","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/369-HI-R-M-0-0-0-H-E.jpg?v=1785923789","url":"https:\/\/www.industriaxplc.com\/products\/ge-multilin-369-hi-r-0-0-0-0-e-motor-protection-relay","provider":"IndustriaX Limited","version":"1.0","type":"link"}