{"product_id":"ge-is210aepsg1b-auxiliary-emergency-power-supply-module","title":"GE IS210AEPSG1B Auxiliary Emergency Power Supply Module","description":"\u003ch2\u003eGE IS210AEPSG1B Auxiliary Emergency Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for emergency DC power conditioning in the GE Mark VIe turbine control system, the \u003cstrong\u003eGE IS210AEPSG1B\u003c\/strong\u003e (\u003cstrong\u003eIS210AEPSG1B\u003c\/strong\u003e Auxiliary Emergency Power Supply Module) provides regulated backup power conversion and status monitoring for critical control and I\/O circuits.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS210AEPSG1B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e168 x 150 x 55 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e125 VDC nominal input, output load dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAuxiliary Emergency Power Supply Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VIe Wind\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003eAEPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Description\u003c\/td\u003e\n\u003ctd\u003eAlternative Energy Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e125 VDC nominal from station battery supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltages\u003c\/td\u003e\n\u003ctd\u003e+5 VDC and +\/-15 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHold-up Time\u003c\/td\u003e\n\u003ctd\u003e50-100 ms after input power loss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd\u003eMicrosecond-level switchover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Functions\u003c\/td\u003e\n\u003ctd\u003eOvervoltage, undervoltage, short-circuit, reverse polarity protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indication\u003c\/td\u003e\n\u003ctd\u003eLED indicators for input, output, and fault status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eHealth and status signals to Mark VIe controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eUniversal Rack (UR) or auxiliary cabinet installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB Coating\u003c\/td\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGE Mark VIe Power Conversion and Control Interface\u003c\/h3\u003e\n\u003cp\u003eThe IS210AEPSG1B integrates regulated DC conversion functions within the Mark VIe control power architecture. The module receives 125 VDC station battery input and generates conditioned DC outputs for selected control and I\/O circuits.\u003c\/p\u003e\n\u003cp\u003eThe module supports industrial control power continuity through fast transfer operation and monitored power status feedback. The design incorporates protection circuits for abnormal input conditions and maintains compatibility with Mark VIe system power distribution requirements.\u003c\/p\u003e\n\u003cp\u003eThe GE industrial control platform supports deterministic control networks, I\/O density scaling, and firmware flash compatibility across approved Mark VIe hardware configurations. The AEPS module operates as a power subsystem component rather than a field signal acquisition device.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input power source is required for the IS210AEPSG1B?\u003cbr\u003eA: The module accepts a nominal 125 VDC input supply from a station battery source.\u003c\/p\u003e\n\u003cp\u003eQ: Which DC outputs are generated by the AEPS module?\u003cbr\u003eA: The module provides +5 VDC and +\/-15 VDC outputs for compatible Mark VIe control and I\/O circuits.\u003c\/p\u003e\n\u003cp\u003eQ: Does the IS210AEPSG1B provide system communication functions?\u003cbr\u003eA: The module provides health and status signals to the Mark VIe controller for power condition monitoring.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS210AEPSG1B in the designated GE Mark VIe rack or auxiliary cabinet position using the approved mechanical mounting and electrical interfaces.\u003c\/p\u003e\n\u003cp\u003eVerify input polarity, DC supply wiring, and connector seating before energizing the module. Route power conductors separately from low-level analog or communication wiring to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eMaintain conformal-coated PCB protection by avoiding unnecessary handling of exposed circuit surfaces. Confirm grounding paths, cabinet bonding, and protective earth connections according to the turbine control cabinet installation requirements.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44403069780056,"sku":"IS210AEPSG1B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS210AEPSG1B_d54409cc-e89e-4b0e-a150-8a793ee95604.jpg?v=1784538320","url":"https:\/\/www.industriaxplc.com\/products\/ge-is210aepsg1b-auxiliary-emergency-power-supply-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}