{"product_id":"ge-is200vaich1cbr-analog-input-module","title":"GE IS200VAICH1CBR Analog Input Module","description":"\u003ch2\u003eGE IS200VAICH1CBR Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS200VAICH1CBR\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200VAICH1CBR\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for analog signal acquisition within the GE Mark VI Turbine Control System. The module provides electrical input processing for turbine monitoring and control functions across VME-based control platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200VAICH1CBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e12 cm (W) x 15.3 cm (H) x 6.8 cm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified in available technical data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module \/ VME Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eMark VI Turbine Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003eVAIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Revision\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eAMD Ryzen Embedded V1000 family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eUp to 8 GB DDR4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e64 GB eMMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB Construction\u003c\/td\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eIEC 61508 compliant, SIL 3 certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility and I\/O Processing Architecture\u003c\/h3\u003e\n\u003cp\u003eThe GE IS200VAICH1CBR module operates within the Mark VI control architecture as an analog signal processing interface. Firmware compatibility defines the operational interaction between the module hardware, control application configuration, and VME communication environment. The conformal-coated PCB design supports operation in industrial turbine control installations where protection against environmental contamination is required.\u003c\/p\u003e\n\u003cp\u003eThe module provides analog input acquisition for turbine control loops, converting field-level analog signals into processed data values used by Mark VI control logic. The analog input density and scaling parameters are managed through system configuration rather than local user adjustment.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the IS200VAICH1CBR designed for hot-swap operation?\u003cbr\u003eA: The available technical data does not specify hot-swap capability. Installation and removal should follow Mark VI rack power isolation procedures.\u003c\/p\u003e\n\u003cp\u003eQ: What type of signal processing function does the module provide?\u003cbr\u003eA: The module performs analog input acquisition and processing for turbine monitoring and control applications within the Mark VI system.\u003c\/p\u003e\n\u003cp\u003eQ: What environmental protection feature is included on the circuit board?\u003cbr\u003eA: The module uses conformal coating on the PCB to provide additional protection against industrial environmental conditions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the VME rack power supply is isolated before module insertion or removal.\u003c\/li\u003e\n\u003cli\u003eInstall the module according to the Mark VI rack slot configuration and system hardware documentation.\u003c\/li\u003e\n\u003cli\u003eMaintain proper field wiring separation between analog signal cables and high-voltage power conductors.\u003c\/li\u003e\n\u003cli\u003eUse appropriate shielding and grounding practices for analog input wiring to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConfirm connector seating and mechanical retention before restoring rack power.\u003c\/li\u003e\n\u003cli\u003eValidate module recognition and input channel operation through the turbine control configuration tools after installation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44341137997912,"sku":"IS200VAICH1CBR","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS200VCMIH1BCD1_6a7469e8-e02a-4f49-bca7-007eed901eb2.jpg?v=1783413704","url":"https:\/\/www.industriaxplc.com\/products\/ge-is200vaich1cbr-analog-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}