{"product_id":"ge-is200tbaih1cdd-terminal-board-for-analog-inputs","title":"GE IS200TBAIH1CDD Terminal Board for Analog Inputs","description":"\u003ch2\u003eGE IS200TBAIH1CDD Terminal Board for Analog Inputs\u003c\/h2\u003e\n\u003cp\u003eConfigured for analog sensor signal termination and conditioning in the GE Mark VI Speedtronic turbine control system, the \u003cstrong\u003eGE IS200TBAIH1CDD\u003c\/strong\u003e (\u003cstrong\u003eIS200TBAI\u003c\/strong\u003e Terminal Board for Analog Inputs) provides direct physical signal routing between field devices and VAIC analog interface boards.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200TBAIH1CDD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive terminal interface board; power supplied through connected control system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTerminal Board for Analog Inputs (TBAI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eGE Mark VI Speedtronic Turbine Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Controller Board\u003c\/td\u003e\n\u003ctd\u003eVAIC (IS200VAICH1CBA and variants)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Channels\u003c\/td\u003e\n\u003ctd\u003e20 analog input channels, 4 analog output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003e+\/-5 V, +\/-10 V, 0-1 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Types\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution Support\u003c\/td\u003e\n\u003ctd\u003e16-bit A\/D and 12-bit D\/A through VAIC interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Format\u003c\/td\u003e\n\u003ctd\u003eDIN rail or chassis mount terminal board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Features\u003c\/td\u003e\n\u003ctd\u003eConformal coating and transient suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Mode Support\u003c\/td\u003e\n\u003ctd\u003eSimplex and TMR configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGE Mark VI Analog Signal Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe IS200TBAIH1CDD provides field wiring termination for voltage and current analog signals before transfer to the VAIC analog input\/output board. The terminal interface maintains signal routing integrity between turbine sensors and the controller processing hardware.\u003c\/p\u003e\n\u003cp\u003eGE Mark VI architecture uses VME-based backplane communication between control modules. The TBAI board functions as the field-side connection point, while the VAIC board performs analog conversion, scaling, and controller data processing.\u003c\/p\u003e\n\u003ch3\u003eFirmware and Backplane Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe board operates within the GE Mark VI control architecture through compatible VME rack interfaces. The module supports simplex and triple modular redundant configurations where multiple control paths require synchronized I\/O signal availability.\u003c\/p\u003e\n\u003cp\u003eThe analog interface design supports I\/O density scaling through Mark VI rack configurations, allowing multiple terminal boards and VAIC modules to be arranged according to turbine instrumentation requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What analog signals can the IS200TBAIH1CDD terminate?\u003cbr\u003eA: The board supports voltage and current analog signals including +\/-5 V, +\/-10 V, 0-1 mA, and 4-20 mA inputs, with analog outputs of 0-20 mA or 4-20 mA through the VAIC interface.\u003c\/p\u003e\n\u003cp\u003eQ: Does the IS200TBAIH1CDD perform analog-to-digital conversion?\u003cbr\u003eA: No. The terminal board provides signal termination and routing. Analog conversion functions are performed by the connected VAIC analog input\/output board.\u003c\/p\u003e\n\u003cp\u003eQ: Can the IS200TBAIH1CDD operate in redundant Mark VI configurations?\u003cbr\u003eA: The board supports installation within simplex and TMR system configurations when used with compatible Mark VI control hardware.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS200TBAIH1CDD in the designated GE Mark VI control cabinet location according to the system hardware configuration. Verify terminal assignments before connecting field wiring from analog sensors.\u003c\/p\u003e\n\u003cp\u003eUse shielded instrumentation cables for low-level analog signals where required. Connect cable shields according to the cabinet grounding scheme and avoid routing analog signal cables parallel to high-current power conductors.\u003c\/p\u003e\n\u003cp\u003eConfirm terminal polarity and signal type before energizing the system. Inspect connectors, terminal screws, and board seating condition during installation and maintenance activities.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44357556797528,"sku":"IS200TBAIH1CDD","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS200TBAIH2C_915f1e53-3744-44a3-b084-9a97863aae8c.jpg?v=1783678468","url":"https:\/\/www.industriaxplc.com\/products\/ge-is200tbaih1cdd-terminal-board-for-analog-inputs","provider":"IndustriaX Limited","version":"1.0","type":"link"}