{"product_id":"ge-is200sptdh2acb-thermocouple-input-termination-board","title":"GE IS200SPTDH2ACB Thermocouple Input\/Termination Board","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eGE IS200SPTDH2ACB Thermocouple Input\/Termination Board\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IS200SPTDH2ACB\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS200SPTD\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThermocouple Input\/Termination Board, operates as a dedicated hardware component for thermocouple signal termination and temperature data conditioning within the GE Mark VI Speedtronic turbine control system. The board interfaces E, J, K, S, and T thermocouple sensors with VTCC input modules through filtered and compensated signal paths.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200SPTDH2ACB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2 x 19 x 26 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eChassis interface supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eThermocouple Input\/Termination Boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eGE Mark VI Speedtronic Turbine Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Types\u003c\/td\u003e\n\u003ctd\u003eE, J, K, S, T thermocouples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e24 inputs, grounded or ungrounded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e-8 mV to +45 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold-Junction Compensation\u003c\/td\u003e\n\u003ctd\u003eIntegrated reference junctions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Filtering\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz interference filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Interface\u003c\/td\u003e\n\u003ctd\u003eDIN rail or chassis integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Features\u003c\/td\u003e\n\u003ctd\u003eConformal coating and overvoltage protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eVTCC input boards for simplex and TMR configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFirmware Flash Compatibility and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe GE IS200SPTDH2ACB provides thermocouple field termination and signal conditioning functions within the Mark VI control architecture. The board routes multiple temperature sensor inputs to compatible VTCC thermocouple processing modules while maintaining signal filtering and cold-junction reference compensation.\u003c\/p\u003e\n\u003cp\u003eThe module supports I\/O density scaling through a 24-channel thermocouple interface arrangement. The terminal board configuration allows simplex and TMR system layouts depending on the associated VTCC controller hardware. Field signal paths are designed for low-level millivolt thermocouple measurements requiring controlled grounding and noise management.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What thermocouple types can be connected to the IS200SPTDH2ACB?\u003cbr\u003eA: The board supports E, J, K, S, and T thermocouple sensor inputs with grounded or ungrounded channel configurations.\u003c\/p\u003e\n\u003cp\u003eQ: What is the function of the cold-junction compensation on this terminal board?\u003cbr\u003eA: The integrated reference junction circuitry compensates for terminal temperature variations to maintain thermocouple measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eQ: Can the IS200SPTDH2ACB be used in redundant Mark VI configurations?\u003cbr\u003eA: The board supports simplex and TMR configurations when paired with compatible VTCC thermocouple input modules.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS200SPTDH2ACB in the specified GE Mark VI control cabinet location and verify compatibility with the connected VTCC input hardware before wiring.\u003c\/p\u003e\n\u003cp\u003eUse shielded thermocouple cables where required and terminate cable shields according to the cabinet grounding design. Keep thermocouple wiring separated from high-current conductors, relay circuits, and switching power cables to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eConfirm thermocouple polarity, channel allocation, and terminal connections before system startup. Check that field wiring insulation, grounding paths, and terminal connections comply with the turbine control system installation documentation.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44357479596120,"sku":"IS200SPTDH2ACB","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS200SPTDH2ACB.jpg?v=1783677496","url":"https:\/\/www.industriaxplc.com\/products\/ge-is200sptdh2acb-thermocouple-input-termination-board","provider":"IndustriaX Limited","version":"1.0","type":"link"}