{"product_id":"ge-is200pscdg1adb-power-supply-contactor-driver-board","title":"GE IS200PSCDG1ADB Power Supply Contactor Driver Board","description":"\u003ch2\u003eGE IS200PSCDG1ADB Power Supply Contactor Driver Board\u003c\/h2\u003e\n\u003cp\u003eConfigured for regulated DC power conversion and contactor control execution in GE Mark VI \/ Mark VIe Speedtronic turbine control systems, the \u003cstrong\u003eGE IS200PSCDG1ADB\u003c\/strong\u003e (\u003cstrong\u003eIS200PSCDG1ADB\u003c\/strong\u003e Power Supply Contactor Driver Board) provides direct electrical execution through DC regulation circuits, isolated I\/O channels, and contactor driver outputs.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200PSCDG1ADB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e16.2 x 8.6 x 4.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e12 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply Contactor Driver Boards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eGE Mark VI \/ Mark VIe Speedtronic turbine control systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Abbreviation\u003c\/td\u003e\n\u003ctd\u003ePSCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e14-32 V DC dual redundant or 88-132 V AC \/ 176-264 V AC depending on configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltages\u003c\/td\u003e\n\u003ctd\u003e+5 V DC, +\/-15 V DC, +\/-24 V DC regulated outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor Driver Output\u003c\/td\u003e\n\u003ctd\u003eUp to 0.75 A DC, 100 V DC output for MDA contactor coils\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e8 differential channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e4 channels, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e16 optically isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e8 relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e32-bit RISC microcontroller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e4 MB Flash, 2 MB battery-backed RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Sampling\u003c\/td\u003e\n\u003ctd\u003e1 kHz per input, 16-bit resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e2500 V optical isolation per I\/O channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eMOV surge protection and conformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackwards Compatibility\u003c\/td\u003e\n\u003ctd\u003eFirst two revisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly Type\u003c\/td\u003e\n\u003ctd\u003eNormal Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGE Mark VI Deterministic Power and I\/O Control\u003c\/h3\u003e\n\u003cp\u003eThe IS200PSCDG1ADB integrates power regulation, contactor driver execution, and signal interface functions within GE Mark VI \/ Mark VIe control architectures. The board supports deterministic backplane communication for status feedback, voltage monitoring, and fault reporting.\u003c\/p\u003e\n\u003cp\u003eThe PSCD board uses redundant power input capability and floating DC bus operation for power distribution management. The floating bus arrangement allows detection of system ground faults while maintaining DC supply separation from earth reference.\u003c\/p\u003e\n\u003cp\u003eThe module provides I\/O density scaling through combined analog and digital interfaces, including differential analog channels, isolated digital inputs, relay outputs, and 4-20 mA analog outputs. Firmware flash compatibility with GE controller environments enables configuration management and diagnostic communication through the turbine control platform.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power outputs are provided by the IS200PSCDG1ADB?\u003cbr\u003eA: The board provides regulated +5 V DC, +\/-15 V DC, and +\/-24 V DC outputs for connected control hardware.\u003c\/p\u003e\n\u003cp\u003eQ: Does the PSCD board support redundant power inputs?\u003cbr\u003eA: Yes. The board supports dual redundant DC input configurations and floating DC bus operation.\u003c\/p\u003e\n\u003cp\u003eQ: What isolation protection is provided for I\/O channels?\u003cbr\u003eA: The board provides 2500 V optical isolation per I\/O channel.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS200PSCDG1ADB in the specified GE Mark VI \/ Mark VIe control cabinet location with correct mounting orientation and connector alignment. Verify all incoming power sources are isolated before performing installation or replacement work.\u003c\/p\u003e\n\u003cp\u003eMaintain separation between DC power wiring, contactor circuits, and low-level analog signal wiring. Use proper grounding practices for cabinet assemblies and connect shields according to GE turbine control installation requirements.\u003c\/p\u003e\n\u003cp\u003eConfirm redundant input polarity, output wiring, and I\/O terminal assignments before energizing the board. After startup, check diagnostic feedback, power status indicators, and backplane communication status through the controller interface.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44387548495960,"sku":"IS200PSCDG1ADB","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS200PSCDG1ADB.jpg?v=1784187192","url":"https:\/\/www.industriaxplc.com\/products\/ge-is200pscdg1adb-power-supply-contactor-driver-board","provider":"IndustriaX Limited","version":"1.0","type":"link"}