{"product_id":"ge-is200aepah1a-analog-expansion-pack","title":"GE IS200AEPAH1A Analog Expansion Pack","description":"\u003ch2\u003eGE IS200AEPAH1A Analog Expansion Pack\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS200AEPAH1A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIS200AEPAH1A\u003c\/strong\u003e Analog Expansion Pack, operates as a dedicated hardware component for analog and discrete signal expansion within GE Mark VI\/Mark VIe turbine control system platforms. It provides additional field I\/O channels for sensor acquisition and actuator interface functions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200AEPAH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Expansion Packs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eGE Mark VI \/ Mark VIe Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Type\u003c\/td\u003e\n\u003ctd\u003eAEPA Analog Expansion Pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Signal Type\u003c\/td\u003e\n\u003ctd\u003eConfigurable 4-20 mA or 0-10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Inputs\u003c\/td\u003e\n\u003ctd\u003e20 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete Outputs\u003c\/td\u003e\n\u003ctd\u003e1 channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Channels\u003c\/td\u003e\n\u003ctd\u003e13 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.05% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC channel-to-channel, 2500 VAC channel-to-ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003eInputs: 5 ms, Outputs: 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eOpen\/short detection, drift monitoring, LED indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC from backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eIEEE C37.90.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGE Mark VI Analog I\/O Expansion Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe IS200AEPAH1A applies GE industrial control architecture for analog signal acquisition and auxiliary I\/O expansion. The board supports I\/O density scaling within Mark VI\/Mark VIe control configurations by combining analog, discrete, and relay interface channels on a single auxiliary assembly.\u003c\/p\u003e\n\u003cp\u003eThe module incorporates GE control platform characteristics including backplane bus communication behavior, deterministic controller interaction, and firmware flash compatibility with the installed Mark VI\/Mark VIe processor configuration.\u003c\/p\u003e\n\u003cp\u003eThe isolated analog signal paths provide separation between field inputs, outputs, and control electronics. The board supports multiple signal formats including current and voltage inputs for turbine sensor monitoring and actuator feedback processing.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What analog input capability is provided by the IS200AEPAH1A?\u003cbr\u003eA: The board provides 8 analog input channels configurable for 4-20 mA or 0-10 VDC signals.\u003c\/p\u003e\n\u003cp\u003eQ: What additional discrete and relay interfaces are available on the board?\u003cbr\u003eA: The available specifications indicate 20 discrete inputs, 1 discrete output, and 8 relay outputs.\u003c\/p\u003e\n\u003cp\u003eQ: What is the operating temperature range of the IS200AEPAH1A?\u003cbr\u003eA: The provided board rating specifies operation from 0 deg C to +60 deg C.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IS200AEPAH1A into the designated GE Mark VI\/Mark VIe rack location and verify correct board alignment before applying power. Secure the assembly according to the system mechanical installation requirements.\u003c\/p\u003e\n\u003cp\u003eUse shielded wiring for analog field connections where required by the cabinet grounding design. Separate low-level signal cables from power conductors and relay switching wiring to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eVerify terminal connections, LED status indicators, and diagnostic feedback after installation. Use ToolboxST diagnostic functions and loopback testing to confirm channel operation before placing the control system into service.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44382911529048,"sku":"IS200AEPAH1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IS200AEPAH1A2.jpg?v=1784108823","url":"https:\/\/www.industriaxplc.com\/products\/ge-is200aepah1a-analog-expansion-pack","provider":"IndustriaX Limited","version":"1.0","type":"link"}