{"product_id":"ge-ic695alg728-rx3i-8-channel-non-isolated-analog-output-module","title":"GE IC695ALG728 RX3i 8-Channel Non-Isolated Analog Output Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IC695ALG728\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an 8-channel analog output module for PACSystems RX3i PLCs, designed for precise process control and monitoring. Featuring HART-enabled diagnostics, this module provides advanced communication with field devices while delivering high-resolution analog outputs. Its non-isolated design supports multiple output ranges, including 4–20 mA and ±10 VDC, with fast update rates and high accuracy, making it ideal for critical industrial applications. The compact form factor saves rack space, and the robust industrial-grade construction ensures reliable operation in demanding environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEight analog output channels supporting flexible voltage and current ranges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHART-enabled diagnostics for enhanced field device communication and monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-resolution outputs (16-bit) with ±0.15% full-scale accuracy at 25°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFast analog update rate (~8 ms across all channels) for responsive control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNon-isolated design with clear grounding guidelines to prevent signal interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact RX3i-compatible form factor for efficient rack integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial-grade reliability for continuous operation in harsh environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eIC695ALG728\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e8-Channel Non-Isolated Analog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 analog outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eCurrent (0–20 mA, 4–20 mA), Voltage (0–10 V, ±10 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.15% full scale at 25°C; ±0.30% at 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e8 ms (all channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Protocol\u003c\/td\u003e\n\u003ctd\u003eVersion 5.0 supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eNon-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Load\u003c\/td\u003e\n\u003ctd\u003e850 Ω (current outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Protection\u003c\/td\u003e\n\u003ctd\u003e-30 V for 60 s, +30 V for 1 hr (current output only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Power Requirement\u003c\/td\u003e\n\u003ctd\u003e380 mA at 3.3 VDC (HART enabled)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply Voltage Range\u003c\/td\u003e\n\u003ctd\u003e19.2–30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7.25 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e142 × 100 × 34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0–60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40–85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5–95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePrecision process control in chemical, petrochemical, and energy industries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil \u0026amp; gas production and refinery systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation and utility monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial manufacturing requiring high-resolution analog control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration with HART-enabled field devices for diagnostic feedback.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module handle both current and voltage outputs?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the IC695ALG728 supports 0–20 mA, 4–20 mA, 0–10 V, and ±10 V output ranges.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it support HART communication?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it includes HART-enabled diagnostics, supporting version 5.0 protocol.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the analog update rate?\u003c\/strong\u003e\u003cbr\u003eA: The module updates all eight channels approximately every 8 milliseconds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the module isolated?\u003c\/strong\u003e\u003cbr\u003eA: No, it is non-isolated. Proper grounding is recommended to prevent interference.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43927496818776,"sku":"IC695ALG728","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IC695ALG728_f8872064-7be4-42cc-858b-612fc89bf1c2.jpg?v=1774868428","url":"https:\/\/www.industriaxplc.com\/products\/ge-ic695alg728-rx3i-8-channel-non-isolated-analog-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}