{"product_id":"ge-ic695acc402-pacsystems-rx3i-capacitor-energy-pack-backup-module","title":"GE IC695ACC402 PACSystems RX3i Capacitor Energy Pack Backup Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC695ACC402\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an energy backup module for the PACSystems RX3i series. Designed to safeguard CPU operation and memory retention during brief power interruptions, this capacitor-based module ensures system reliability without the need for batteries. It provides seamless, temporary energy support for critical control operations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\/Part Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC695ACC402\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: GE Intelligent Platforms (Emerson Automation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e: PACSystems RX3i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e: Capacitor-based Energy Pack (backup power accessory)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e: Supplies temporary energy to CPU and memory during power interruptions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Controllers\u003c\/strong\u003e: RX3i CPE330 CPU and related modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackup Duration\u003c\/strong\u003e: Maintains CPU operation for several minutes, depending on system load\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Storage Technology\u003c\/strong\u003e: Advanced capacitor pack (no batteries required)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e: Input 20–30 VDC, Output 18–30 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Output Current\u003c\/strong\u003e: 2.25 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Output Power\u003c\/strong\u003e: 45 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Input Power\u003c\/strong\u003e: 36 W plus connected device requirement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDedicated Cable\u003c\/strong\u003e: IC695CBL002A (36” \/ 1 m)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e: DIN rail or direct panel mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e: LEDs show energy status (IN, STAT, OUT)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e: Included grounding terminal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitor Life Expectancy\u003c\/strong\u003e: ~5 years\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement Capacitor Pack\u003c\/strong\u003e: IC695ACC412\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: –25 to 60 °C (32–140 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: –40 to 85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e: 5–95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e: UL, CE, CSA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 1.0 lbs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCapacitor-based design eliminates battery maintenance requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic energy backup protects CPU memory and logic during power loss\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLED diagnostics provide clear indication of module status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlexible installation via DIN rail or panel mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField-upgradeable firmware delivered through CPU firmware updates\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact design integrates seamlessly into PACSystems RX3i racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eShort-term backup for RX3i CPU and memory during power interruptions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCritical process control systems requiring uninterrupted operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement or upgrade for RX3i CPE330 CPU energy packs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How long does the backup last?\u003c\/strong\u003e\u003cbr\u003eA: Typically several minutes, depending on CPU load and connected devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module require batteries?\u003c\/strong\u003e\u003cbr\u003eA: No, it uses a capacitor-based energy storage system for maintenance-free operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the firmware be updated?\u003c\/strong\u003e\u003cbr\u003eA: Yes, updates are delivered through compatible CPU firmware.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43895210836056,"sku":"IC695ACC402","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IC695ACC402.jpg?v=1774001785","url":"https:\/\/www.industriaxplc.com\/products\/ge-ic695acc402-pacsystems-rx3i-capacitor-energy-pack-backup-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}