{"product_id":"ge-ic694mdl240a-16-point-120-vac-discrete-input-module","title":"GE IC694MDL240A 16-Point 120 VAC Discrete Input Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC694MDL240A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 16-channel discrete AC input module for the PACSystems RX3i series. Engineered for industrial control applications, it accepts 120 VAC signals from devices such as pushbuttons, limit switches, and proximity sensors. Its robust electrical isolation protects both the module and the system, while integrated LED indicators provide immediate visual status for each input.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\/Part Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC694MDL240A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e: GE Intelligent Platforms (GE Fanuc)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e: PACSystems RX3i\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Discrete Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e: 16 (single group)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e: 120 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e: 0–132 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e: 47–63 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e: ~12 mA per channel at rated voltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Voltage\u003c\/strong\u003e: 5 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Current Draw\u003c\/strong\u003e: 90 mA (all inputs active)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eField-to-backplane: 250 VAC continuous\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField-to-frame: 1500 VAC for 1 minute\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLED Indicators\u003c\/strong\u003e: 16 green LEDs for ON\/OFF status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOn-State Voltage\u003c\/strong\u003e: 74–132 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOn-State Current\u003c\/strong\u003e: 6 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOff-State Voltage\u003c\/strong\u003e: 0–20 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOff-State Current\u003c\/strong\u003e: 2.2 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOn: typical 30 ms, maximum 30 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOff: maximum 45 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0–60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 5.5 in x 5.5 in x 1.5 in (14.0 cm x 14.0 cm x 3.8 cm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.56 lbs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHandles 120 VAC signals for industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with standard input devices including pushbuttons, limit switches, and proximity sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh isolation ensures electrical safety and system reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e16 LED indicators provide instant diagnostics of input status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for easy installation into any RX3i I\/O slot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMonitoring AC input devices in factory automation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrating field input signals into PACSystems RX3i controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafe signal acquisition for machinery and process control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExpansion of I\/O capabilities for discrete AC monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module handle other AC voltages?\u003c\/strong\u003e\u003cbr\u003eA: It is optimized for 120 VAC; operation outside 0–132 VAC range is not recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is electrical isolation maintained?\u003c\/strong\u003e\u003cbr\u003eA: The module provides 250 VAC continuous isolation between field wiring and backplane, and 1500 VAC for 1 minute to frame ground.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are LED indicators available for each channel?\u003c\/strong\u003e\u003cbr\u003eA: Yes, each of the 16 input channels has a green LED showing ON\/OFF status.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the module dimensions and weight?\u003c\/strong\u003e\u003cbr\u003eA: Dimensions: 5.5 in x 5.5 in x 1.5 in; Weight: 0.56 lbs.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43895136813144,"sku":"IC694MDL240A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IC694MDL240A.jpg?v=1773994718","url":"https:\/\/www.industriaxplc.com\/products\/ge-ic694mdl240a-16-point-120-vac-discrete-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}