{"product_id":"ge-ic200uex626-plc-analog-expansion-module","title":"GE IC200UEX626 PLC Analog Expansion Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200UEX626\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a compact analog expansion unit developed for the VersaMax Micro PLC platform, enabling additional analog signal handling in space-limited or distributed control systems. It integrates four analog input channels and two analog output channels within a single module, allowing accurate acquisition and control of process variables such as voltage or current signals.\u003c\/p\u003e\n\u003cp\u003eDesigned for flexible deployment, this module can be installed remotely up to 2 meters from the base controller, making it suitable for panel layouts where direct mounting is not practical. Communication is handled via an RS-485 interface, ensuring reliable data exchange between the expansion module and the Micro PLC.\u003c\/p\u003e\n\u003cp\u003eWith low power consumption and a rugged mechanical design, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200UEX626\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis well-suited for continuous operation in demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCombined analog input and output expansion in a single module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports remote installation up to 2 meters from controller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRS-485 communication for stable data transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDIN-rail mounting for standard control cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact footprint for space-constrained applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for VersaMax Micro and compatible Nano systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTotal Channels: 6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnalog Inputs: 4 channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnalog Outputs: 2 channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Parameters\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupply Voltage: 24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Range: 19.2 to 30 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Consumption: approx. 3 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSensor Supply Current: up to 200 mA (field devices)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInterface Type: RS-485 serial communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFunction: Expansion module data exchange with Micro PLC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation \u0026amp; Mounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Method: DIN rail\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMax दूरी from Controller: 2 meters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfiguration: Modular expansion architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: –20 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: –40 °C to +85 °C (typical for this class)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity: 5% to 95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Data\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 143.3 × 78.8 × 61.3 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.22 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200UEX626\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule is typically applied in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProcess signal monitoring (temperature, pressure, flow)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnalog control loops in small PLC systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDistributed I\/O layouts in compact control panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUtility systems and building automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOEM machinery requiring scalable analog expansion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of signals can the analog inputs handle?\u003c\/strong\u003e\u003cbr\u003eA: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200UEX626\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etypically supports standard industrial analog signals such as 0–10 V or 4–20 mA, depending on configuration and system setup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module operate independently of the PLC?\u003c\/strong\u003e\u003cbr\u003eA: No. It functions strictly as an expansion module and must be connected to a VersaMax Micro controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How far can the module be installed from the PLC?\u003c\/strong\u003e\u003cbr\u003eA: Installation distance is limited to 2 meters to maintain communication integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is additional communication hardware required?\u003c\/strong\u003e\u003cbr\u003eA: No additional modules are required, as RS-485 communication is integrated.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43998469521496,"sku":"IC200UEX626","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IC200UEX626.jpg?v=1776245936","url":"https:\/\/www.industriaxplc.com\/products\/ge-ic200uex626-plc-analog-expansion-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}