{"product_id":"ge-ic200udr040-versamax-micro-plc-40-point-relay","title":"GE IC200UDR040 VersaMax Micro PLC 40 Point Relay","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200UDR040\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom GE Fanuc is a compact 40-point programmable logic controller designed for discrete machine control applications requiring a mix of high-density digital inputs and electromechanical relay outputs.\u003c\/p\u003e\n\u003cp\u003eThis unit integrates input processing, relay switching, high-speed counting capability, and onboard power distribution into a single controller body, making it suitable for standalone machine-level automation without external expansion hardware.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTotal I\/O capacity: 40 points\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDigital inputs: 24 × 24 VDC configurable logic inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDigital outputs: 16 × relay (Form A \/ SPST, normally open)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe controller supports mixed logic input configurations (sink\/source wiring), enabling flexible field device integration.\u003c\/p\u003e\n\u003cp\u003eA subset of inputs is dedicated to high-speed event capture for counting applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupply voltage: 24 VDC nominal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating range: 19.2–30 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower consumption: approx. 5 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput current draw: ~0.2 A typical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInrush current: up to 1 A at 30 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHold-up time: ~10 ms at low voltage threshold\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInternal auxiliary power:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e+24 VDC sensor supply output: up to 435 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAuxiliary +5 V pin (serial interface): up to 100 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDigital Input Specifications (24 Channels)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInput voltage range: 0–30 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNominal input: 24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLogic type: selectable positive or negative field wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput current:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-sensitivity channels: ~8 mA typical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard channels: ~4.8 mA typical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHigh-speed counter capability:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 4 × Type A counters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOr 1 × Type A + 1 × Type B configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResolution: 16-bit or 32-bit counter modes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTypical applications: encoder pulse tracking, fast switching sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInput devices supported:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProximity switches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLimit switches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePushbuttons\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePulse generators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eRelay Output Specifications (16 Channels)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOutput type: electromechanical relay (Form A, SPST, normally open)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoad rating: 2 A per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput power type: external AC or DC field supply required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSwitching characteristic: on\/off only (no PWM or high-speed switching capability)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTypical loads:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSolenoid valves\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMotor contactor coils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal lamps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGeneral-purpose resistive or inductive loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRelay isolation provides strong separation between field power and control logic circuits.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProcessing and Control Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEmbedded high-speed counting engine with multi-mode configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e16-bit and 32-bit register support for extended count ranges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInternal +24 VDC distribution for limited field device powering\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigurable logic handling for flexible input interpretation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMemory and System Operation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFlash memory: firmware and application storage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetentive RAM: capacitor-backed runtime data retention\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem architecture supports fast boot recovery and stable program retention under power interruption conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 1.43 lb\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact 40-point integrated controller housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDIN rail or panel mounting via terminal base system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHinged terminal cover for wiring protection and maintenance access\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating temperature: 0°C to 60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for enclosed industrial control enclosures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical isolation between field wiring and internal logic circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePackaging machinery control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConveyor and material handling systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMachine automation with relay-based load switching\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVAC and pump control panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOEM equipment requiring mixed I\/O control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan relay outputs support PWM or fast switching?\u003c\/strong\u003e\u003cbr\u003eNo. The outputs are mechanical relays and are intended for low-frequency switching only.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this PLC support high-speed counting?\u003c\/strong\u003e\u003cbr\u003eYes. It supports up to four high-speed counter configurations with 16-bit or 32-bit resolution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs external power required for outputs?\u003c\/strong\u003e\u003cbr\u003eYes. Relay outputs require an external AC or DC load supply.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43971678765144,"sku":"IC200UDR040","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IC200UDR040.jpg?v=1775805789","url":"https:\/\/www.industriaxplc.com\/products\/ge-ic200udr040-versamax-micro-plc-40-point-relay","provider":"IndustriaX Limited","version":"1.0","type":"link"}