{"product_id":"ge-ic200pns002-profinet-scanner-module","title":"GE IC200PNS002 PROFINET Scanner Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200PNS002 \u003c\/strong\u003ePROFINET Scanner Module from GE’s VersaMax platform enables seamless integration of distributed I\/O stations into PROFINET networks. Acting as a PROFINET IO-Device, the module continuously exchanges real-time data with an IO-Controller while managing local I\/O modules and maintaining deterministic communication performance.\u003c\/p\u003e\n\u003cp\u003eDesigned for fiber-optic industrial networks, this unit supports high-speed data transmission, ring redundancy, and advanced diagnostics. It is particularly suited for applications requiring reliable communication in electrically noisy or long-distance environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFunctions as a PROFINET IO-Device (Conformance Class A)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated fiber-optic interface for EMI-resistant communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports Media Redundancy Protocol (MRP) for ring topology resilience\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigurable I\/O update intervals for deterministic control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in diagnostics, alarms, and fault handling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRedundant power capability for improved system uptime\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic scanning and management of local VersaMax I\/O modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Type: PROFINET Scanner Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeries: VersaMax\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModel:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200PNS002\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManufacturer: GE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCountry of Origin: United States\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork \u0026amp; Communication\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePROFINET Standard: Version 2.2, Class A IO-Device\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePhysical Ports:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e2 × 100 Mbps SC Duplex Multi-Mode Fiber (MMF)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eSupported Network Topologies: Line, Star, Ring (MRP Client)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP Addressing: CIDR-compatible (subnetting supported)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMAC Address Allocation: 3 (dual external + internal interface)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUpdate Cycle Time: Adjustable from 1 ms to 512 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFull node scan of installed I\/O modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCyclic input data transmission to IO-Controller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput data reception and execution from controller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommunication watchdog and fail-safe I\/O fallback behavior\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated alarm and diagnostic messaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupply Voltage: 5 VDC via backplane\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent Consumption: Approx. 1.10 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Redundancy: Supported (hot-swap for inactive supply)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.48 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eService Port: Micro-USB (firmware updates only)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eStandard: 0°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExtended (variant dependent): −40°C to +70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eHazardous Area Certification:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eClass I, Division 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eATEX II 3G (for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200PNS002-AA\u003c\/strong\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum Modules per Station: 8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess Data Size:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInput: up to 1440 bytes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput: up to 1440 bytes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis module is widely used in distributed automation systems where fiber-optic networking and deterministic communication are required, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDiscrete and process manufacturing lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation and distribution systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater and wastewater treatment plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTransportation and infrastructure control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary role of this module in a PROFINET network?\u003c\/strong\u003e\u003cbr\u003eA: It operates as an IO-Device, exchanging cyclic I\/O data with a PROFINET IO-Controller while managing local VersaMax I\/O modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module support network redundancy?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports MRP (Media Redundancy Protocol) in client mode, enabling ring topology redundancy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it be used in harsh or hazardous environments?\u003c\/strong\u003e\u003cbr\u003eA: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200PNS002-AA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evariant is certified for Class I Division 2 and ATEX Zone 2 environments, making it suitable for hazardous locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is copper Ethernet supported?\u003c\/strong\u003e\u003cbr\u003eA: No, this model is equipped with fiber-optic SC ports only, designed for high-noise or long-distance installations.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43998432362584,"sku":"IC200PNS002","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IC200PNS002.jpg?v=1776244929","url":"https:\/\/www.industriaxplc.com\/products\/ge-ic200pns002-profinet-scanner-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}