{"product_id":"ge-ic200mdl750-versamax-i-o-output-module","title":"GE IC200MDL750 VersaMax I\/O Output Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200MDL750\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density discrete output module designed for the GE Fanuc \/ Emerson VersaMax I\/O system. It provides 32-channel sourcing (positive logic) DC outputs for distributed control applications requiring reliable switching of field devices such as solenoids, relays, indicators, and similar DC loads.\u003c\/p\u003e\n\u003cp\u003eThe module installs on VersaMax I\/O carrier bases and communicates through the backplane while using an external field power supply for load energization.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe output structure is divided into two independent banks of 16 channels, allowing structured field wiring and load separation.\u003c\/p\u003e\n\u003cp\u003eKey functional characteristics:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e32 sourcing DC output channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePositive logic high-side switching configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTwo isolated 16-point output groups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndividual LED status indicators per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOK and Field Power diagnostic LEDs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane-powered control logic with external field supply\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Performance Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Voltage Range: 10.2 to 30 VDC (12\/24 VDC nominal systems)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Current: 0.5 A per channel (resistive load)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInrush Current Capability: up to 2 A for 100 ms per point\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane Current Consumption: approximately 90 mA at 5 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSwitching Speed:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTurn ON: 0.2 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTurn OFF: 1.0 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Type: DC sourcing (positive logic only)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese parameters support fast-response discrete control in compact I\/O architectures.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIsolation and Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eField-to-backplane isolation: 250 VAC continuous\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDielectric withstand: 1500 VAC for 1 minute\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGroup isolation between two 16-channel banks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNo point-to-point isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInductive loads should be externally suppressed using flyback diodes, RC snubbers, or equivalent protection methods to ensure long-term reliability.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWiring and System Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTwo field power groups with 16 outputs each\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShared DC+ and DC− terminals per group\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExternal 12\/24 VDC field power required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for VersaMax DIN-rail carrier systems (IC200CHS series)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental and Mechanical Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: 0 to 60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: DIN-rail via VersaMax I\/O carrier base\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHazardous Area Rating: Class I, Division 2 (when installed per control drawings)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.29 lb\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e32 individual channel LEDs for output status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOK LED indicating module health\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFLD PWR LED indicating field power availability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese diagnostics support fast commissioning and fault identification in the field.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSolenoid valve control in process systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelay and contactor interposing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial panel indicator control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMachine-level discrete output expansion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDistributed control system I\/O architectures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of loads can this module drive?\u003c\/strong\u003e\u003cbr\u003eIt supports DC resistive and inductive loads such as solenoids, relays, and indicator lamps.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it require external power?\u003c\/strong\u003e\u003cbr\u003eYes, a 12\/24 VDC external field power supply is required for operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it suitable for hazardous environments?\u003c\/strong\u003e\u003cbr\u003eIt is rated for Class I, Division 2 installations when applied according to Emerson installation guidelines.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43971556048984,"sku":"IC200MDL750","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IC200MDL750C.jpg?v=1775803418","url":"https:\/\/www.industriaxplc.com\/products\/ge-ic200mdl750-versamax-i-o-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}