{"product_id":"ge-ic200mdl730-discrete-dc-output-module","title":"GE IC200MDL730 Discrete DC Output Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200MDL730\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom GE Fanuc (Emerson) is an 8-channel 24 VDC discrete output module, designed for reliable control of field devices in industrial automation systems. It supports positive‑logic (sourcing) outputs, allowing the module to supply current directly to loads such as relays, solenoids, indicator lamps, and small actuators.\u003c\/p\u003e\n\u003cp\u003eEach output point is protected against short circuits and overcurrent conditions, ensuring both module and field wiring safety. Integrated LEDs for every channel, plus OK and Field Power (FLD PWR) indicators, provide fast diagnostics and operational status monitoring.\u003c\/p\u003e\n\u003cp\u003eThe module mounts on any VersaMax I\/O carrier and supports both DIN‑rail and panel installation, offering flexible deployment in compact control cabinets.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Channel Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTotal outputs: 8 points, single group\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput type: Positive‑logic, sourcing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoad current capacity: 2.0 A per output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNominal output voltage: 24 VDC (range 17.5–30 VDC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum switching frequency: 10 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eProtection \u0026amp; Reliability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eShort-circuit protection on each output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOvercurrent protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFault indication via amber LED\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDetected faults reported to VersaMax CPU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese features ensure safe operation and quick fault identification in demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower \u0026amp; Electrical Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane supply: 5 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane current draw: 50 mA max\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExternal field power: 18–30 VDC nominal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module operates entirely from the VersaMax backplane for logic power, while driving external loads from a dedicated 24 VDC field supply.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIndicators \u0026amp; Diagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne LED per output channel for status monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOK LED for module health\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFLD PWR LED for field power availability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAmber fault LED for overcurrent or short circuit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese visual indicators simplify troubleshooting and maintenance.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical \u0026amp; Environmental Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 110 × 66.8 × 50 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.38 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: VersaMax I\/O carriers (DIN-rail or panel)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating temperature: 0°C to 60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage temperature: –40°C to +70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelative humidity: 5%–95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e8 discrete sourcing outputs at 24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh load handling: 2 A per point\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in short-circuit and overcurrent protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndividual point LEDs, plus OK and FLD PWR indicators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFast response: ~0.5 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact VersaMax form factor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eControl of relays, solenoids, and lamps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSmall actuator and motor control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMachine automation requiring reliable digital outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetrofit or expansion of existing VersaMax systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module drive inductive loads?\u003c\/strong\u003e\u003cbr\u003eA: Yes, but external protection (flyback diodes or snubbers) is recommended for inductive devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module require external power for logic operation?\u003c\/strong\u003e\u003cbr\u003eA: No. Logic power is supplied via the VersaMax backplane; external 24 VDC is only needed for the outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens if a short circuit occurs?\u003c\/strong\u003e\u003cbr\u003eA: The affected output is protected by the built-in overcurrent circuit, and an amber fault LED is illuminated.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43968921698392,"sku":"IC200MDL730","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IC200MDL730E.jpg?v=1775732603","url":"https:\/\/www.industriaxplc.com\/products\/ge-ic200mdl730-discrete-dc-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}