{"product_id":"ge-ic200mdd840-versamax-mixed-discrete-i-o-module","title":"GE IC200MDD840 VersaMax Mixed Discrete I\/O Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200MDD840\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a hybrid discrete I\/O module from GE Fanuc (Emerson) designed for the VersaMax platform. It integrates both digital inputs and relay outputs within a single module, allowing efficient handling of sensing and control tasks in compact automation systems.\u003c\/p\u003e\n\u003cp\u003eThis module combines 24 VDC sourcing inputs with electromechanical relay outputs, making it adaptable to both low-voltage control signals and higher-voltage load switching. It is commonly used in machine control panels where space optimization and wiring simplification are required.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eI\/O Configuration Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTotal I\/O channels: 32\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDigital inputs: 20 channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelay outputs: 12 channels (Form A, normally open)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe mixed configuration reduces the need for separate input and output modules, simplifying system design and reducing installation footprint.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInput type: Positive logic (sourcing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNominal voltage: 24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating range: 0 to 30 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput current (ON state): 2.0 to 5.5 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput current (OFF state): up to 0.5 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput impedance: ≤10 kΩ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResponse time:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eON: 0.5 ms typical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOFF: 10 ms typical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese characteristics ensure reliable signal detection from sensors such as proximity switches, pushbuttons, and limit switches.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOutput type: Relay contacts (Form A, normally open)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNumber of outputs: 12\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContact ratings:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e2 A at 5–265 VAC (resistive load)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 A at 5–30 VDC (resistive load)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0.2 A at 31–125 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eMinimum switching load: 10 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput grouping:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTwo isolated groups of 6 outputs each (typical design architecture)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNote: External protection devices (such as snubbers or fuses) are recommended for inductive loads.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane current draw: up to 375 mA at 5 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExternal supply range:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e0–125 VDC (nominal 5 \/ 24 \/ 125 VDC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0–265 VAC (47–63 Hz, nominal 120 \/ 240 VAC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDiagnostics and Indicators\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIndividual LED indicators for each input and output point\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDedicated module status LED (OK indicator)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese indicators provide immediate visual feedback for commissioning and troubleshooting.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 110 × 66.8 × 50 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.35 lb\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Compatible with VersaMax carrier bases (IC200CHS series)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating temperature: –20°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelative humidity: 5% to 95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDesigned for stable operation in industrial control cabinets with typical environmental stress factors.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Functional Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCombined input and output functionality in one module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports both DC sensing and AC\/DC load switching\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelay outputs provide electrical isolation from field loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLED diagnostics for each channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSpace-efficient solution for mixed I\/O requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePackaging and assembly machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConveyor and material handling systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOEM equipment panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGeneral-purpose discrete control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApplications requiring both sensor input and relay-driven output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module drive inductive loads such as solenoids?\u003c\/strong\u003e\u003cbr\u003eA: Yes, but external suppression components (e.g., RC snubbers or flyback diodes) are recommended to protect relay contacts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are the outputs electrically isolated?\u003c\/strong\u003e\u003cbr\u003eA: The relay contacts provide isolation from the control electronics, and outputs are typically grouped for load segmentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module require a separate power supply for outputs?\u003c\/strong\u003e\u003cbr\u003eA: Yes. External power must be supplied according to the load voltage requirements.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43968916979800,"sku":"IC200MDD840","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IC200MDD840G.jpg?v=1775732034","url":"https:\/\/www.industriaxplc.com\/products\/ge-ic200mdd840-versamax-mixed-discrete-i-o-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}