{"product_id":"ge-ic200cpu002-versamax-plc-cpu-module","title":"GE IC200CPU002 VersaMax PLC CPU Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CPU002\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a higher-capacity CPU module within the GE Fanuc (Emerson) VersaMax family, developed for modular control systems requiring more memory and expanded communication flexibility than entry-level CPUs. It integrates processing, memory management, and serial communications into a compact unit suitable for distributed and standalone PLC architectures.\u003c\/p\u003e\n\u003cp\u003eWith increased user memory and support for both Modbus master and slave communication, this CPU is well suited for applications involving data exchange with multiple field devices, operator interfaces, and supervisory systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProcessing Performance and Memory\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUser-configurable memory: 42 KB (program logic, registers, and analog data)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExecution rate: 1.8 ms per 1K Boolean instructions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFloating-point capability: Supported\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRuntime overrides: Available\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe system uses non-volatile flash for firmware storage combined with battery-backed RAM for application data retention, ensuring continuity during power interruptions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eI\/O Handling Capacity\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDiscrete Inputs: 2048 channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiscrete Outputs: 2048 channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInternal Discrete Memory: 1024 bits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemporary Logic Bits: 256\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGlobal Memory Bits: 1280\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis configuration supports medium-scale automation systems with distributed I\/O structures.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Interfaces\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in ports:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 × RS-232\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × RS-485\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eSupported communication protocols:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSNP Slave\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModbus RTU Master and Slave\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSerial I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe addition of Modbus Master capability allows this CPU to actively poll and control external devices such as drives and instrumentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMemory System and Data Retention\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProgram storage: Embedded flash memory\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWorking memory: Battery-backed RAM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time clock: Integrated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTime accuracy:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e±2 seconds\/day at 30°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUp to ±9 seconds\/day across full temperature range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eBattery life: Typically up to 5 years under normal conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane current consumption:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e5 VDC: 40 mA (base) \/ up to 140 mA with expansion devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e3.3 VDC: 100 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.99 lbs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Installs on VersaMax carrier base\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStatus Indicators: Integrated LED diagnostics for system and communication status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMode Selection: Physical RUN\/STOP switch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating temperature: 0°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage temperature: –40°C to +85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for industrial environments with standard vibration and electrical noise tolerance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Functional Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eExpanded 42 KB memory for more complex control strategies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDual serial ports with Modbus RTU Master\/Slave capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery-backed clock and memory retention\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated diagnostics and hardware mode selector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with full VersaMax I\/O range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDistributed I\/O control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePackaging and assembly automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater treatment and utilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOEM equipment with serial device integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess control systems requiring Modbus master communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the main difference between IC200CPU001 and IC200CPU002?\u003c\/strong\u003e\u003cbr\u003eA: The IC200CPU002 provides larger memory (42 KB vs 34 KB) and adds Modbus RTU Master functionality, making it more suitable for complex and communication-intensive applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this CPU communicate with multiple Modbus devices?\u003c\/strong\u003e\u003cbr\u003eA: Yes. Using the RS-485 port in Modbus Master mode, it can poll and manage multiple slave devices on the same network.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module retain data after power loss?\u003c\/strong\u003e\u003cbr\u003eA: Yes. Battery-backed RAM preserves program and runtime data, and the real-time clock continues operating.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43968914358360,"sku":"IC200CPU002","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IC200CPU002-EF.jpg?v=1775731557","url":"https:\/\/www.industriaxplc.com\/products\/ge-ic200cpu002-versamax-plc-cpu-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}