{"product_id":"ge-ic200chs025-i-o-carrier-module","title":"GE IC200CHS025 I\/O Carrier Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CHS025\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a compact VersaMax carrier unit engineered by GE Fanuc Emerson for direct mounting of a single I\/O module within a distributed control rack. It integrates field wiring termination, backplane interface routing, and mechanical module retention into a single vertical-format carrier.\u003c\/p\u003e\n\u003cp\u003eDesigned for space-constrained control panels, this model uses spring-clamp terminal technology to simplify wiring installation while maintaining reliable electrical contact and vibration resistance.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical Structure and Installation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis carrier is optimized for high-density cabinet layouts and supports both DIN rail and panel mounting configurations.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDIN rail mounting: 35 mm standard (EN 50022)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional direct panel mounting for high-vibration environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVertical module orientation for compact rack arrangement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated keying system to prevent incorrect module placement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure latch mechanism for stable module retention\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCarrier-to-carrier interconnect support for backplane continuity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWiring Interface Design\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CHS025\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euses spring-loaded IEC terminal technology to reduce installation time and eliminate the need for specialized tools.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e36 spring-clamp terminals total\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports up to 32 signal I\/O connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncludes 4 dedicated common\/power terminals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with single or dual conductor wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWire compatibility:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSingle wire: AWG 14–22\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDual wire: AWG 18\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis design improves wiring density while reducing maintenance errors in field installations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum operating voltage: 264 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTransient voltage withstand: up to 300 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eI\/O capacity: up to 32 points per carrier (module dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower distribution: supplied through mounted VersaMax I\/O module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for low-resistance signal continuity across backplane interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe carrier functions as a structural and electrical interface for VersaMax I\/O modules, ensuring stable communication with the system backplane while maintaining correct module alignment and grounding continuity.\u003c\/p\u003e\n\u003cp\u003eIt is compatible with a wide range of VersaMax digital and analog I\/O modules used in modular control architectures.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating temperature range: -40°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVertical spacing requirement: 2 inches\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHorizontal spacing requirement: 1 inch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDIN rail grounding required for EMC compliance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConductive, corrosion-resistant rail surface recommended\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eLength: 163.5 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWidth: 66.8 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDepth: 70 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.68 lbs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCompact PLC I\/O expansion systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-density control cabinet wiring layouts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMachine-level modular automation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetrofit installation of VersaMax I\/O platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration-sensitive industrial control panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What type of wiring system does this carrier use?\u003c\/strong\u003e\u003cbr\u003eIt uses 36 spring-loaded IEC terminals for tool-free wire insertion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can it be installed without DIN rail mounting?\u003c\/strong\u003e\u003cbr\u003eYes, it supports optional panel mounting for environments with higher vibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How many I\/O points does it support?\u003c\/strong\u003e\u003cbr\u003eIt supports up to 32 I\/O channels plus 4 common\/power connections depending on module configuration.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43988172701784,"sku":"IC200CHS025","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IC200CHS025_44ebc86c-284e-4005-b0e3-047fe8ca13f2.jpg?v=1776075003","url":"https:\/\/www.industriaxplc.com\/products\/ge-ic200chs025-i-o-carrier-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}