{"product_id":"ge-ic200cbl002-plc-communication-cable","title":"GE IC200CBL002 PLC Communication Cable","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CBL002 \u003c\/strong\u003eis a dedicated communication cable used within GE VersaMax control systems for configuration, programming, and device communication. It is primarily designed to establish a reliable connection between a Network Interface Unit (NIU) and a PC, enabling system setup, firmware updates, and diagnostics.\u003c\/p\u003e\n\u003cp\u003eIn the field, this part number is also associated with different variants, including a 3-meter industrial communication cable with M12 connectors and, in some cases, a compact system-bus interface assembly. Regardless of the variation, all versions are engineered to maintain high signal integrity and stable communication under industrial conditions.\u003c\/p\u003e\n\u003cp\u003eThe cable features robust shielding and industrial-grade insulation, ensuring resistance to electromagnetic interference and long-term durability in control cabinets and factory environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for NIU-to-PC programming and configuration tasks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielded construction for improved noise immunity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial connector options including M12 (depending on version)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for system integration and communication diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDurable cable jacket for harsh environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports stable, high-integrity data transmission\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePart Number:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CBL002 (44A770487-001R01)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable Type: Communication \/ programming cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTypical Length: 3 meters (cable version)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Type: M12 or dedicated interface connector (variant dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.1 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Type: Low-voltage digital communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum Data Rate: up to 10 Mbps (cable version)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsulation Voltage Rating: up to 300 V AC\/DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Yes (EMI-resistant design)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Ratings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: –20 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: –40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtection Class: up to IP67 (for M12 connector variant)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOptional Variant (System-Bus Interface Type)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCommunication Bandwidth: up to 100 Mbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupply Voltage: 24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Consumption: \u0026lt; 5 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupported Protocols: Modbus, Profibus, DeviceNet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: –40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CBL002\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis commonly used for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnecting VersaMax NIU modules to a PC for configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePLC programming and firmware updates\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShort-distance communication between automation devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem diagnostics and commissioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial communication networks requiring shielded cabling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary function of this cable?\u003c\/strong\u003e\u003cbr\u003eA: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CBL002 (44A770487-001R01)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis mainly used for connecting a VersaMax NIU to a computer for configuration and maintenance tasks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are there multiple versions of this part number?\u003c\/strong\u003e\u003cbr\u003eA: Yes. It may refer to either a programming cable or a communication cable assembly depending on the supplier listing. Always verify connector type and specifications before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the cable suitable for industrial environments?\u003c\/strong\u003e\u003cbr\u003eA: Yes. It is designed with shielding and durable insulation to withstand electrical noise and harsh conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it support high-speed communication?\u003c\/strong\u003e\u003cbr\u003eA: The standard cable supports up to 10 Mbps, while some associated module variants support higher bandwidth.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43998483742808,"sku":"IC200CBL002","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IC200CBL002.jpg?v=1776246314","url":"https:\/\/www.industriaxplc.com\/products\/ge-ic200cbl002-plc-communication-cable","provider":"IndustriaX Limited","version":"1.0","type":"link"}