{"product_id":"ge-fanuc-series-one-ic610mdl129-input-module","title":"GE Fanuc Series One IC610MDL129 16-Channel AC Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe IC610MDL129 is a 16-channel discrete AC input module designed for integration within the legacy GE Fanuc Series One programmable controller platform. It serves as a robust interface for processing field signals from devices such as pushbuttons, selector switches, and relay contacts in demanding industrial environments. By converting high-voltage field signals into logic-level data, this module ensures reliable signal processing and system availability. The design features a field-replaceable terminal block to streamline maintenance and reduce mean time to repair (MTTR).\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16-channel discrete AC input configuration.\u003c\/li\u003e\n\u003cli\u003eTwo isolated groups of eight channels each, allowing for dual power source compatibility.\u003c\/li\u003e\n\u003cli\u003eIntegrated logic-side status indicators for real-time diagnostic feedback.\u003c\/li\u003e\n\u003cli\u003eRemovable terminal board for simplified field wiring and maintenance.\u003c\/li\u003e\n\u003cli\u003eOptimized for Series One backplane integration in both primary and expansion rack configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is suitable for legacy automation control systems in industries such as water treatment, mining operations, and assembly manufacturing where 115 VAC discrete signal monitoring is required.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC610MDL129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eSeries One\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAC Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 (2 groups of 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e115 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e80 to 132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e14.5 mA at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-Level Voltage\u003c\/td\u003e\n\u003ctd\u003eAbove 80 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-Level Voltage\u003c\/td\u003e\n\u003ctd\u003eBelow 15 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time (Off-to-On)\u003c\/td\u003e\n\u003ctd\u003e5 to 50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time (On-to-Off)\u003c\/td\u003e\n\u003ctd\u003e5 to 60 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Power Consumption\u003c\/td\u003e\n\u003ctd\u003e64 mA at 9 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is disconnected before installing or removing the module from the Series One backplane.\u003c\/li\u003e\n\u003cli\u003eVerify that the input voltage levels match the module specifications (80-132 VAC) to prevent damage.\u003c\/li\u003e\n\u003cli\u003eUse the removable terminal block for field wiring; ensure all connections are secure and properly torqued.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation within the enclosure to ensure the module operates within its specified 0 to 60 deg C temperature range.\u003c\/li\u003e\n\u003cli\u003eRoute field wiring away from high-voltage AC lines or high-EMI sources to minimize signal interference.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eCan this module be used in an expansion rack?\u003c\/strong\u003e Yes, the IC610MDL129 is compatible with Series One expansion racks, supporting up to 5 modules in a 5-slot rack or 10 modules in a 10-slot rack.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the isolation configuration of this module?\u003c\/strong\u003e The module features 16 input circuits divided into two isolated groups of eight, allowing the module to monitor inputs from two different power sources simultaneously.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":44598127951960,"sku":"IC610MDL129","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/wm_1_b3a4c2df-5652-41f0-9254-aecb16eb57d4.jpg?v=1786724216","url":"https:\/\/www.industriaxplc.com\/products\/ge-fanuc-series-one-ic610mdl129-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}