{"product_id":"ge-fanuc-ic695alg808-rx3i-high-density-analog-input-module","title":"GE Fanuc IC695ALG808 RX3i High-Density Analog Input Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC695ALG808\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance analog input module designed for the PACSystems RX3i PLC series. It provides 16 high-accuracy channels for voltage and current signals, enabling precise process monitoring and control in complex automation systems.\u003c\/p\u003e\n\u003cp\u003eThis module supports multiple input ranges, including ±10 VDC, 0–20 mA, and 4–20 mA, making it compatible with a wide array of industrial sensors and transmitters. With 16-bit resolution and ±0.1% full-scale accuracy, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC695ALG808\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures reliable measurement and fast data acquisition for real-time applications.\u003c\/p\u003e\n\u003cp\u003eFeaturing channel-to-ground isolation, the module delivers robust noise immunity, critical for maintaining signal integrity in industrial environments. The removable terminal block simplifies sensor wiring, while the single-slot design allows efficient use of rack space in the RX3i system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIC695ALG808\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePACSystems RX3i\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Ranges\u003c\/td\u003e\n\u003ctd\u003e±10 VDC, 0–20 mA, 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e2550 VDC field-to-backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e8 milliseconds (all channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Filter Response\u003c\/td\u003e\n\u003ctd\u003e17 Hz typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Connections\u003c\/td\u003e\n\u003ctd\u003eRemovable terminal block (requires IC694TBB032 or IC694TBS032)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Requirement\u003c\/td\u003e\n\u003ctd\u003eSingle-slot module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Power\u003c\/td\u003e\n\u003ctd\u003e80 mA max @ 3.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power\u003c\/td\u003e\n\u003ctd\u003e19.2–30 VDC (24 V nominal), 160 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Settling Time\u003c\/td\u003e\n\u003ctd\u003e2 ms (0–95%, voltage or current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Format\u003c\/td\u003e\n\u003ctd\u003eIEEE 32-bit floating point, 16-bit integer in 32-bit field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.65 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features \u0026amp; Benefits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eHigh-Density Inputs: 16 channels maximize rack efficiency and reduce hardware requirements.\u003cbr\u003eFlexible Signal Compatibility: Accepts voltage and current signals from various industrial sensors.\u003cbr\u003eHigh Accuracy: 16-bit resolution and ±0.1% full-scale precision enable precise process monitoring.\u003cbr\u003eNoise-Resistant Design: Channel isolation ensures stable operation in electrically noisy environments.\u003cbr\u003eEfficient Rack Integration: Single-slot design simplifies installation in RX3i systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProcess monitoring in chemical, food \u0026amp; beverage, and pharmaceutical industries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData acquisition from multiple analog sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMachine control and monitoring for large-scale automation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time signal processing in SCADA and HMI applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many analog inputs does the IC695ALG808 support?\u003c\/strong\u003e\u003cbr\u003eA: Each module provides 16 analog input channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which input ranges are supported?\u003c\/strong\u003e\u003cbr\u003eA: Voltage ranges ±10 VDC, current ranges 0–20 mA and 4–20 mA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it require a specific terminal block?\u003c\/strong\u003e\u003cbr\u003eA: Yes, either IC694TBB032 or IC694TBS032 is recommended for proper wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the update rate for all channels?\u003c\/strong\u003e\u003cbr\u003eA: Approximately 8 milliseconds for simultaneous conversion of all 16 channels.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43919095332952,"sku":"IC695ALG808","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IC695ALG808_77fb11b5-11d4-4ff5-820d-7895ea293a81.jpg?v=1774601650","url":"https:\/\/www.industriaxplc.com\/products\/ge-fanuc-ic695alg808-rx3i-high-density-analog-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}