{"product_id":"ge-fanuc-ic693pwr324-series-90-30-ac-dc-30w-power-supply-module","title":"GE Fanuc IC693PWR324 Series 90-30 AC\/DC 30W Power Supply Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693PWR324\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eby GE Fanuc is a 30‑Watt AC\/DC power supply module designed for the Series 90‑30 PLC platform. It installs in the leftmost slot of the baseplate and delivers three regulated DC outputs to power CPUs, I\/O modules, relay circuits, and internal electronics. With wide-range input compatibility, integrated protection features, and RS‑485 diagnostic support, this module ensures reliable PLC operation across diverse industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWide-range input: 85–264 VAC (50\/60 Hz) or 100–300 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThree independent DC outputs: +5 VDC for logic, +24 VDC for relays, and isolated +24 VDC for internal circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtection mechanisms: overvoltage, overcurrent, and short-circuit shutdown\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHoldup time ≥20 ms at full load to maintain system stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDetachable terminal block for simplified wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStatus LEDs: PWR, OK, RUN, BATT for quick visual monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRS‑485 communication for diagnostics and monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFanless operation with compact design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eInput Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNominal Input Voltage: 120\/240 VAC or 125 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Voltage Range: 85–264 VAC \/ 100–300 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Power: 90 VA (AC) \/ 50 W (DC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePeak Inrush Current: 4 A, 250 ms maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eOutput Channel\u003c\/th\u003e\n\u003cth\u003eVoltage Range\u003c\/th\u003e\n\u003cth\u003eMax Power\u003c\/th\u003e\n\u003cth\u003eTypical Use\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e+5 VDC\u003c\/td\u003e\n\u003ctd\u003e5.0–5.2 VDC\u003c\/td\u003e\n\u003ctd\u003e15 W\u003c\/td\u003e\n\u003ctd\u003eCPU \u0026amp; logic circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+24 VDC (Relay)\u003c\/td\u003e\n\u003ctd\u003e24–28 VDC\u003c\/td\u003e\n\u003ctd\u003e15 W\u003c\/td\u003e\n\u003ctd\u003eRelay modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e+24 VDC (Isolated)\u003c\/td\u003e\n\u003ctd\u003e21.5–28 VDC\u003c\/td\u003e\n\u003ctd\u003e20 W\u003c\/td\u003e\n\u003ctd\u003eInput modules \/ internal circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Output Capacity\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e30 W\u003c\/td\u003e\n\u003ctd\u003eModule rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eProtection \u0026amp; Performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOvervoltage: 5 VDC shuts down at 6.4–7 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOvercurrent: 5 VDC limited to 4 A max\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShort-Circuit: Automatic shutdown\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHoldup Time: ≥20 ms at full load\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Leftmost slot of Series 90‑30 baseplate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: 0°C to 60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity: 5–95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 3.6 × 13 × 13.5 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.86 lbs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupplying power to Series 90‑30 CPUs, I\/O modules, and relay circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial automation systems requiring stable multi-rail DC outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystems needing wide-range AC\/DC input compatibility without additional power conversion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApplications where diagnostic monitoring via RS‑485 is essential\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module accept both AC and DC inputs simultaneously?\u003c\/strong\u003e\u003cbr\u003eA: The module supports AC or DC input, but each installation should use only one type at a time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What protection features are included?\u003c\/strong\u003e\u003cbr\u003eA: Overvoltage, overcurrent, and short-circuit protection automatically safeguard connected equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the module indicate operational status?\u003c\/strong\u003e\u003cbr\u003eA: Four LEDs display power (PWR), system health (OK), run status (RUN), and battery\/auxiliary power (BATT).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are there higher capacity alternatives for more demanding PLC loads?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the IC693PWR332 provides higher output power while maintaining multi-rail regulation and wide AC\/DC input support.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":43948156682328,"sku":"IC693PWR324","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IC693PWR322_8e7d073a-030d-44b8-a98c-b6804e96491f.jpg?v=1775122106","url":"https:\/\/www.industriaxplc.com\/products\/ge-fanuc-ic693pwr324-series-90-30-ac-dc-30w-power-supply-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}