{"product_id":"ge-fanuc-ic200mdl744-versamax-32-point-output-module","title":"GE Fanuc IC200MDL744 VersaMax 32 Point Output Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200MDL744\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density discrete output module from the GE Fanuc Emerson VersaMax series, designed for digital signal switching in compact I\/O systems. It supports multiple output voltage configurations, making it suitable for both TTL-level control and standard DC load driving applications.\u003c\/p\u003e\n\u003cp\u003eThe module is organized into two output groups and provides per-point status indication for fast diagnostics and maintenance efficiency in distributed control environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200MDL744\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGE Fanuc \/ Emerson\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVersaMax\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDiscrete Output Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Output Points:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32 channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNegative logic (sinking type)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Groups:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 isolated groups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eElectrical Ratings\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTTL Mode Output Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4.75–5.25 V DC (5 V nominal)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDC Load Mode Output Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10.2–30 V DC (12\/24 V nominal operation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 0.5 A per point (application dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eIsolation \u0026amp; Protection\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGroup-to-Group Isolation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e250 V AC continuous\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1500 V AC for 1 minute\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePoint-to-Point Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNot provided\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo internal fuse (external protection recommended)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePower \u0026amp; Diagnostics\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Power Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e~140 mA at 5 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule ID:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e80808080\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndicators:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne LED per output channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStatus LEDs: OK and Field Power (FLD PWR)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.98 lb\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IC200MDL744 provides flexible output switching for both low-voltage logic control and standard DC actuator driving. Its dual-voltage capability allows integration into mixed-signal systems without requiring additional interface modules.\u003c\/p\u003e\n\u003cp\u003ePer-channel LED indicators simplify troubleshooting by providing immediate visual confirmation of output activity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMachine automation control outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelay and actuator switching systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMixed-voltage control panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact VersaMax distributed output architectures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOEM equipment requiring high-density digital output control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThis module operates as a sinking-type (negative logic) output device and requires proper external load design to ensure safe switching performance. Since no internal fusing is included, external protective devices are recommended for inductive or high-current loads.\u003c\/p\u003e\n\u003cp\u003eProper grouping of loads per output bank is essential to maintain isolation integrity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What type of outputs does the IC200MDL744 provide?\u003c\/strong\u003e\u003cbr\u003eIt provides 32 sinking (negative logic) discrete outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can it operate at both 5V and 24V systems?\u003c\/strong\u003e\u003cbr\u003eYes, it supports TTL-level 5V operation as well as 12\/24V DC load switching.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is internal protection included?\u003c\/strong\u003e\u003cbr\u003eNo internal fuse is provided; external protection is recommended.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44004574560344,"sku":"IC200MDL744","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/IC200MDL744.jpg?v=1776416831","url":"https:\/\/www.industriaxplc.com\/products\/ge-fanuc-ic200mdl744-versamax-32-point-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}