{"product_id":"ge-ds200tctgg1a-mark-v-simplex-trip-board","title":"GE DS200TCTGG1A Mark V Simplex Trip Board","description":"\u003ch2\u003eGE DS200TCTGG1A Mark V Simplex Trip Board\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE DS200TCTGG1A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200TCTGG1A\u003c\/strong\u003e Simplex Trip Board, operates as a dedicated hardware component for turbine protection signal processing and trip solenoid control within the GE Speedtronic Mark V turbine control system.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200TCTGG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSpeedtronic Mark V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Type\u003c\/td\u003e\n\u003ctd\u003eSimplex Trip Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Application\u003c\/td\u003e\n\u003ctd\u003eTurbine Trip Solenoid Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Configuration\u003c\/td\u003e\n\u003ctd\u003e21 plug-in electro-mechanical trip relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Rating\u003c\/td\u003e\n\u003ctd\u003e120 VDC \/ 125 VDC rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signals\u003c\/td\u003e\n\u003ctd\u003eEmergency Stop, Overspeed Trip, Flame Detection, Loss of Lube Oil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003eThree 50-pin connectors and two 12-pin connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB Coating\u003c\/td\u003e\n\u003ctd\u003eNormal Coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet-IP Deterministic Control Network Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe DS200TCTGG1A is designed as a Mark V turbine control hardware board and does not function as a direct industrial network communication module. Its interface operation is based on turbine control signal routing, relay execution, and terminal connections within the Speedtronic architecture. Hardware integration requires verification of backplane interfaces, terminal assignments, and firmware compatibility within the installed Mark V control configuration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the DS200TCTGG1A support hot-swap replacement during turbine operation?\u003cbr\u003eA: The DS200TCTGG1A is a turbine protection board for the Mark V control system. Hot-swap operation is not specified in the available technical documentation. Replacement should follow approved turbine shutdown and maintenance procedures.\u003c\/p\u003e\n\u003cp\u003eQ: What trip functions are processed by the DS200TCTGG1A?\u003cbr\u003eA: The board processes emergency trip-related signals including Emergency Stop, overspeed trip, flame detection, and loss of lube oil conditions through onboard trip relay circuits.\u003c\/p\u003e\n\u003cp\u003eQ: How is the board connected within the Mark V system?\u003cbr\u003eA: The DS200TCTGG1A uses ribbon cable interfaces and screw terminal connections, including three 50-pin connectors and two 12-pin connectors for control system integration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the DS200TCTGG1A in the designated Mark V turbine control cabinet slot according to the system hardware configuration documentation. Verify connector alignment before insertion and avoid mechanical stress on ribbon cable assemblies.\u003c\/p\u003e\n\u003cp\u003eUse proper grounding practices for the control cabinet chassis and ensure cable shields are terminated according to the site electrical standard. Separate low-level control wiring from high-energy switching circuits to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning, verify relay terminal wiring, trip circuit continuity, and emergency shutdown signal paths. Confirm that the installed board revision matches the existing Speedtronic Mark V hardware configuration.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44479745917016,"sku":"DS200TCTGG1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DS200TCRAG1A_1.jpg?v=1785401567","url":"https:\/\/www.industriaxplc.com\/products\/ge-ds200tctgg1a-mark-v-simplex-trip-board","provider":"IndustriaX Limited","version":"1.0","type":"link"}