{"product_id":"ge-ds200tbqcg1a-analog-input-milliamp-i-o-termination-module","title":"GE DS200TBQCG1A Analog Input \/ Milliamp I\/O Termination Module","description":"\u003ch2\u003eGE DS200TBQCG1A Analog Input \/ Milliamp I\/O Termination Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for analog signal acquisition, conditioning, and field termination in the Mark V Speedtronic turbine control system, the \u003cstrong\u003eGE DS200TBQCG1A\u003c\/strong\u003e (\u003cstrong\u003eDS200TBQC\u003c\/strong\u003e Analog Input \/ Milliamp I\/O Termination Module) provides direct electrical interface between field devices and the TCQA board installed within the RST control cores. The \u003cstrong\u003eDS200TBQCG1A\u003c\/strong\u003e supports 4-20 mA signal routing, LVDT\/R position inputs, and configurable milliamp output channels through dedicated terminal and connector assemblies.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe available revision variants identify hardware revision levels rather than different functional products.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDS200TBQCG1A\u003c\/td\u003e\n\u003ctd\u003eBase Analog Input \/ Milliamp I\/O Termination Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDS200TBQCG1AAA\u003c\/td\u003e\n\u003ctd\u003eHardware revision variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDS200TBQCG1ABB\u003c\/td\u003e\n\u003ctd\u003eHardware revision variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200TBQCG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE General Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input \/ Milliamp I\/O Termination Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark V Speedtronic (DS200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Description\u003c\/td\u003e\n\u003ctd\u003eRST Analog Termination Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003eTBQC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Location\u003c\/td\u003e\n\u003ctd\u003eRST cores (R1, R2, R3), Position 9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Board\u003c\/td\u003e\n\u003ctd\u003eTCQA Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e4-20 mA input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosition Inputs\u003c\/td\u003e\n\u003ctd\u003eLVDT\/R position inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003eConfigurable 20 mA or 200 mA output range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Blocks\u003c\/td\u003e\n\u003ctd\u003e2 terminal blocks (TB1, TB2), 166 total terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003e3 x 40-pin, 3 x 34-pin, 1 x TEST port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJumper Configuration\u003c\/td\u003e\n\u003ctd\u003eBJ1-BJ17 hardware jumpers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB Coating\u003c\/td\u003e\n\u003ctd\u003eNormal Coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.35 kg to 0.75 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified by manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module exchanges field I\/O signals with the associated TCQA board through dedicated multi-pin connectors installed within the Mark V backplane architecture. JBR transfers 4-20 mA input and output current signals, while JFR carries LVDT\/R position signals. Auxiliary headers (JBS, JBT, JFS, and JFT) are reserved for system expansion or background functions. Hardware jumpers provide local channel configuration without altering application firmware. Compatibility should be verified against the installed Mark V hardware revision before replacement.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the DS200TBQCG1A support hot-swapping during turbine operation?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied documentation does not specify hot-swap capability. Installation or replacement should follow the controller maintenance procedure with power removed from the affected hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the purpose of jumpers BJ16 and BJ17?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e BJ16 and BJ17 select the maximum output current range for the two milliamp output channels, allowing configuration for either 20 mA or 200 mA operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the function of the TEST connector?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The TEST port provides a diagnostic connection for field measurement and maintenance activities using appropriate test instruments.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the module is installed in the designated RST core position before connecting field wiring.\u003c\/li\u003e\n\u003cli\u003eLabel conductors according to the TB1 and TB2 terminal numbering to maintain traceability during maintenance.\u003c\/li\u003e\n\u003cli\u003eRoute analog signal wiring separately from high-voltage or high-current conductors to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eTerminate cable shields according to the control cabinet grounding practice and avoid multiple shield ground points unless specified by the system design.\u003c\/li\u003e\n\u003cli\u003eConfirm jumper positions before energizing the system, particularly BJ16 and BJ17 when configuring output current ranges.\u003c\/li\u003e\n\u003cli\u003eInspect all multi-pin connectors for complete engagement before returning the controller to service.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44480046825560,"sku":"DS200TBQCG1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DS200TBQCG1ABB_19619161-c3d2-4d9d-a615-74c3d0aa0d79.jpg?v=1785402682","url":"https:\/\/www.industriaxplc.com\/products\/ge-ds200tbqcg1a-analog-input-milliamp-i-o-termination-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}