{"product_id":"ge-ds200dtbdg1a-contact-output-expansion-termination-module","title":"GE DS200DTBDG1A Contact Output Expansion Termination Module","description":"\u003ch2\u003eGE DS200DTBDG1A Contact Output Expansion Termination Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for contact output expansion and field signal termination in the Speedtronic Mark V \/ Mark V LM control system, the \u003cstrong\u003eGE DS200DTBDG1A\u003c\/strong\u003e (\u003cstrong\u003eDS200DTBD\u003c\/strong\u003e Contact Output Expansion Termination Module) provides direct electrical execution. The board functions as a termination interface for digital\/contact outputs, enabling electrical connection between the controller and external devices including relays, solenoids, and ignition converters.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200DTBDG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eContact Output Expansion Termination Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Category\u003c\/td\u003e\n\u003ctd\u003eTermination Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003eDTBD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl System\u003c\/td\u003e\n\u003ctd\u003eSpeedtronic Mark V \/ Mark V LM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOriginal Product Series\u003c\/td\u003e\n\u003ctd\u003eMark V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Revision\u003c\/td\u003e\n\u003ctd\u003eG1A (Revision 1A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCB Protection\u003c\/td\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Function\u003c\/td\u003e\n\u003ctd\u003eContact output expansion and field termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Field Devices\u003c\/td\u003e\n\u003ctd\u003eSolenoids, relays, ignition converters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eControl cabinet PCB installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe DS200DTBDG1A is designed for operation within the GE Speedtronic Mark V \/ Mark V LM hardware architecture. Correct board selection requires matching the specified functional revision and approved firmware configuration of the associated controller. The G1A revision identifies the hardware revision of the termination board and should be verified before replacement to maintain compatibility with the installed control cabinet configuration.\u003c\/p\u003e\n\u003cp\u003eThe module operates as a termination interface rather than an independent controller. Contact output commands are transferred through the Mark V backplane architecture to the DTBD board, where field wiring is terminated and routed to external output devices. Conformal coating provides additional protection of the PCB against moisture, dust, and industrial contaminants.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the DS200DTBDG1A generate output signals independently?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. It functions as a termination and expansion module. Output commands originate from the associated Mark V control electronics and are routed through the termination board to connected field devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the module be replaced while the control cabinet remains energized?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Available documentation does not specify hot-swap capability. Replacement should follow the applicable Mark V maintenance procedure with the equipment placed in a safe de-energized state unless the manufacturer explicitly specifies otherwise.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is conformal coating applied to the PCB?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The conformal coating reduces exposure of PCB conductors and components to moisture, dust, and airborne contaminants commonly encountered inside industrial control cabinets.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the complete part number and hardware revision before installation.\u003c\/li\u003e\n\u003cli\u003eDe-energize the control cabinet according to plant lockout and isolation procedures before removing or installing the board.\u003c\/li\u003e\n\u003cli\u003eEnsure the module is fully seated in its mounting position and all connectors are correctly aligned before applying power.\u003c\/li\u003e\n\u003cli\u003eRoute field wiring separately from high-voltage or high-current conductors to minimize electrical interference.\u003c\/li\u003e\n\u003cli\u003eTerminate cable shields according to the grounding practice specified for the Mark V control cabinet to reduce noise coupling.\u003c\/li\u003e\n\u003cli\u003eInspect connectors and terminal points for contamination or mechanical damage before commissioning.\u003c\/li\u003e\n\u003cli\u003eAfter installation, verify continuity and confirm correct operation of each connected relay, solenoid, or ignition converter through standard commissioning procedures.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":44479979749464,"sku":"DS200DTBDG1A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/DS200DTBAG1A_241a98a4-f3af-40cc-a96c-d3e20af5f991.jpg?v=1785402389","url":"https:\/\/www.industriaxplc.com\/products\/ge-ds200dtbdg1a-contact-output-expansion-termination-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}