{"product_id":"fs-sdo-0824-honeywell-safe-digital-output-module","title":"FS-SDO-0824 Honeywell Safe Digital Output Module","description":"\u003ch2\u003eHoneywell FS-SDO-0824 Safe Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FS-SDO-0824\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSDO-0824\u003c\/strong\u003e Safe Digital Output Module, operates as a dedicated hardware component for fail-safe output switching within Honeywell Safety Manager and Fail Safe Control (FSC) system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFS-SDO-0824 \/ SDO-0824\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSafe Digital Output Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4 TE, 3 HE rack space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eDerates to 350 mA per channel at 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC supply: 25 mA; 24 VDC internal supply: 25 mA; 24 VDC external supply: 70 mA without load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd\u003eUp to SIL 3 according to IEC 61508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8 isolated output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSolid-state high-side sourcing output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Continuous Current\u003c\/td\u003e\n\u003ctd\u003e550 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Lamp Load\u003c\/td\u003e\n\u003ctd\u003e120 mA, 2.9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Capacitance\u003c\/td\u003e\n\u003ctd\u003e1 uF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Drop\u003c\/td\u003e\n\u003ctd\u003eLess than 2.0 VDC at 500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Leakage Current\u003c\/td\u003e\n\u003ctd\u003eLess than 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWatchdog Input Current\u003c\/td\u003e\n\u003ctd\u003e8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, TUV, UL, CSA, FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating Type\u003c\/td\u003e\n\u003ctd\u003eNon-conformal coated FS version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFail-Safe Output Switching and Isolation\u003c\/h3\u003e\n\u003cp\u003eThe FS-SDO-0824 provides eight isolated solid-state sourcing channels for direct control of external electrical loads. Each output channel incorporates short-circuit protection and diagnostic monitoring functions to supervise connected field circuits.\u003c\/p\u003e\n\u003cp\u003eAdditionally, the module separates outputs into two groups of four channels. Each group includes Secondary Means of De-energization (SMOD) hardware, which supports fail-safe output interruption during safety system demand conditions.\u003c\/p\u003e\n\u003cp\u003eThe module performs continuous diagnostic checks to detect output faults, open circuits, short circuits, and internal hardware abnormalities. Therefore, the safety controller can evaluate output circuit status during operation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the FS-SDO-0824 support fail-safe output operation for SIL 3 applications?\u003cbr\u003eA: Yes. The module is designed for fail-safe digital output control and supports applications up to SIL 3 according to IEC 61508 when applied within the approved Honeywell safety system architecture.\u003c\/p\u003e\n\u003cp\u003eQ: What type of loads can the FS-SDO-0824 control?\u003cbr\u003eA: The module supports resistive, inductive, and lamp loads, including devices such as solenoids, relays, contactors, and indicators within specified electrical limits.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module provide electrical isolation between output channels?\u003cbr\u003eA: Yes. The FS-SDO-0824 provides isolated output channels with integrated protection and diagnostic functions for individual field circuits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module only in compatible Honeywell Safety Manager or FSC rack assemblies.\u003c\/li\u003e\n\u003cli\u003eVerify the module position and connector alignment before inserting the hardware into the rack.\u003c\/li\u003e\n\u003cli\u003eConnect field wiring according to the approved Honeywell wiring documentation.\u003c\/li\u003e\n\u003cli\u003eSeparate output wiring from high-voltage switching conductors to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eUse appropriate grounding and shielding practices for connected field devices.\u003c\/li\u003e\n\u003cli\u003eConfirm load polarity and external supply connections before applying system power.\u003c\/li\u003e\n\u003cli\u003eInspect terminal connections periodically to maintain correct electrical contact.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44407832051800,"sku":"FS-SDO-824","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/FS-SDO-824.jpg?v=1784624813","url":"https:\/\/www.industriaxplc.com\/products\/fs-sdo-0824-honeywell-safe-digital-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}