{"product_id":"fc-tsdo-1624-honeywell-digital-output-modules","title":"FC-TSDO-1624 Honeywell | Digital Output Modules","description":"\u003ch2\u003eHoneywell FC-TSDO-1624 Fail-Safe Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-TSDO-1624\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFC-TSDO-1624\u003c\/strong\u003e Fail-Safe Digital Output Module, operates as a dedicated hardware component for 24 VDC safety output execution within Honeywell Safety Manager systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-TSDO-1624\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFail-Safe Digital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Safety Manager \/ Safety Manager SC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDepends on field load and module configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 independent digital output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSourcing digital output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd\u003eSupports SIL 3 applications according to IEC 61508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Monitoring\u003c\/td\u003e\n\u003ctd\u003eOpen circuit and short circuit detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between field circuits and system electronics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indication\u003c\/td\u003e\n\u003ctd\u003eChannel-level LED status and fault indication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eSupports redundant safety system configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHoneywell Safety Manager Digital Output Execution Technology\u003c\/h3\u003e\n\u003cp\u003eThe FC-TSDO-1624 provides controlled 24 VDC output switching for safety-related field devices connected to Honeywell Safety Manager platforms. Moreover, the module performs continuous diagnostics on output circuits to detect abnormal field conditions, including wiring faults and load-side failures.\u003c\/p\u003e\n\u003cp\u003eThe module architecture incorporates galvanic isolation between the internal safety controller interface and external field wiring. Therefore, electrical disturbances from connected actuators, relays, or solenoid loads remain separated from the controller electronics.\u003c\/p\u003e\n\u003cp\u003eIn addition, the module supports fail-safe state execution by forcing defined output conditions during detected internal or external faults. The 16-channel design allows individual monitoring and control of multiple safety output circuits within a configured safety application.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the FC-TSDO-1624 support hot-swapping in a Safety Manager configuration?\u003cbr\u003eA: The module can support replacement procedures in compatible Safety Manager redundant configurations. The exact hot-swap operation depends on the installed system architecture and configuration rules.\u003c\/p\u003e\n\u003cp\u003eQ: What type of field signals can the FC-TSDO-1624 control?\u003cbr\u003eA: The module provides 24 VDC sourcing digital outputs for safety field devices such as actuators, valves, and relay interfaces.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module detect output circuit faults?\u003cbr\u003eA: The FC-TSDO-1624 uses integrated diagnostics to monitor output channel conditions and identify open circuit or short circuit faults.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the FC-TSDO-1624 according to the Honeywell Safety Manager hardware installation requirements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module in the designated Safety Manager rack position with correct mechanical alignment.\u003c\/li\u003e\n\u003cli\u003eVerify that field wiring uses appropriate separation between safety circuits and high-energy power conductors.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to the system grounding design to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eConfirm polarity and terminal assignments before applying 24 VDC field power.\u003c\/li\u003e\n\u003cli\u003eCheck output loop continuity and actuator wiring before commissioning.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation and cabinet environmental control according to the installed control system specifications.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44376289312856,"sku":"FC-TSDO-1624","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/FC-TSDO-1624-3.jpg?v=1784015966","url":"https:\/\/www.industriaxplc.com\/products\/fc-tsdo-1624-honeywell-digital-output-modules","provider":"IndustriaX Limited","version":"1.0","type":"link"}