{"product_id":"f3pu30-0s-power-supply-module-yokogawa-mitsubishi-electric","title":"F3PU30-0S Power Supply Module | Yokogawa Mitsubishi Electric","description":"\u003ch2\u003eYokogawa Mitsubishi Electric F3PU30-0S Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for power conversion and backplane power distribution in Mitsubishi Electric PLC systems, the \u003cstrong\u003eMitsubishi Electric F3PU30-0S\u003c\/strong\u003e (\u003cstrong\u003eF3PU30\u003c\/strong\u003e Power Supply Module) provides direct electrical execution. The module accepts a single-phase AC input and delivers regulated 5 V DC output for system operation. It supports operation under specified input voltage fluctuation conditions and incorporates insulation and dielectric withstand characteristics for industrial control environments.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3PU30-0S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eMitsubishi Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e100 - 240 V AC, single-phase, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85 - 264 V AC, 50\/60 Hz +\/- 3 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e100 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e20 A max. at 120 V AC (Ta = 25 degC); 45 A max. at 240 V AC (Ta = 25 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Voltage\u003c\/td\u003e\n\u003ctd\u003e5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current\u003c\/td\u003e\n\u003ctd\u003e2.0 A \/ 4.3 A \/ 6.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e5 Mohm min. at 500 V DC between AC terminals and FG; 5 Mohm min. at 500 V DC between FAIL contact group and internal circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1500 V AC for 1 minute between AC terminals and FG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Momentary Power Failure\u003c\/td\u003e\n\u003ctd\u003e20 ms (Standard Mode); 10 ms (Immediate Detection Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Immunity\u003c\/td\u003e\n\u003ctd\u003e1500 Vp-p, 1 us pulse width, 1 ns rise time, 25 - 60 Hz repetition frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e58 mm (W) x 100 mm (H) x 126.1 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e380 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Power Distribution and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe F3PU30-0S functions as the power source for associated PLC hardware through the system backplane. Correct installation requires verification that the aggregate current consumption of connected modules remains within the available output capacity. Firmware compatibility is determined by the host PLC platform and associated system modules; no firmware-specific restrictions are stated in the supplied specification.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the F3PU30-0S provide isolation between the AC input and protective ground?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The module specifies an insulation resistance of 5 Mohm or greater at 500 V DC and a dielectric withstand voltage of 1500 V AC for 1 minute between external AC terminals and the FG terminal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What occurs during a short-duration power interruption?\u003c\/strong\u003e\u003cbr\u003eA: The module specifies an allowable momentary power failure time of 20 ms in Standard Mode and 10 ms in Immediate Detection Mode.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What output voltage is supplied by the module?\u003c\/strong\u003e\u003cbr\u003eA: The rated output voltage is 5 V DC. The specification lists output current ratings of 2.0 A, 4.3 A, and 6.0 A depending on the configured system requirements.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module according to the mechanical orientation specified by the host PLC rack or base unit.\u003c\/li\u003e\n\u003cli\u003eVerify that incoming power wiring matches the specified 100 - 240 V AC single-phase supply requirements.\u003c\/li\u003e\n\u003cli\u003eConnect protective earth (FG) using a low-impedance grounding conductor in accordance with site electrical standards.\u003c\/li\u003e\n\u003cli\u003eSeparate AC input wiring from signal and communication cables to minimize conducted and radiated noise coupling.\u003c\/li\u003e\n\u003cli\u003eConfirm that total downstream module current demand does not exceed the available 5 V DC output capacity.\u003c\/li\u003e\n\u003cli\u003eInspect terminal tightness and grounding continuity before energizing the system.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate enclosure ventilation to support thermal dissipation during continuous operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44162989129816,"sku":"F3PU30-0S","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/F3PU30-0S.jpg?v=1780277976","url":"https:\/\/www.industriaxplc.com\/products\/f3pu30-0s-power-supply-module-yokogawa-mitsubishi-electric","provider":"IndustriaX Limited","version":"1.0","type":"link"}