{"product_id":"f3bu13-0n-fa-m3-base-module-yokogawa","title":"F3BU13-0N  | FA-M3 Base Module Yokogawa","description":"\u003ch2\u003eYokogawa F3BU13-0N FA-M3 Base Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa F3BU13-0N\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eF3BU13-0N\u003c\/strong\u003e Base Module, operates as a dedicated hardware component for slot-based module hosting within FA-M3 controller platforms. It provides structured physical and electrical interconnection for CPUs, power units, and I\/O modules, ensuring deterministic signal routing across the backplane.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 100%; height: 254.719px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 25.2181%; height: 19.5938px;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width: 71.4485%; height: 19.5938px;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.2181%; height: 19.5938px;\"\u003eModelBrand\u003c\/td\u003e\n\u003ctd style=\"width: 71.4485%; height: 19.5938px;\"\u003eYokogawa F3BU13-0N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.2181%; height: 19.5938px;\"\u003eOrigin\u003c\/td\u003e\n\u003ctd style=\"width: 71.4485%; height: 19.5938px;\"\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.2181%; height: 19.5938px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 71.4485%; height: 19.5938px;\"\u003e0.47 kg (unpopulated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.2181%; height: 19.5938px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 71.4485%; height: 19.5938px;\"\u003e13-slot standard rack, compatible with FA-M3 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.2181%; height: 19.5938px;\"\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd style=\"width: 71.4485%; height: 19.5938px;\"\u003e0 to 55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.2181%; height: 19.5938px;\"\u003eStorageTemp\u003c\/td\u003e\n\u003ctd style=\"width: 71.4485%; height: 19.5938px;\"\u003e-20 to 75 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.2181%; height: 19.5938px;\"\u003eRelativeHumidity\u003c\/td\u003e\n\u003ctd style=\"width: 71.4485%; height: 19.5938px;\"\u003e10% to 90% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 25.2181%; height: 19.5938px;\"\u003eAtmosphere\u003c\/td\u003e\n\u003ctd style=\"width: 71.4485%; height: 19.5938px;\"\u003eIndoor use, free from corrosive or flammable gases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 25.2181%; height: 39.1875px;\"\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd style=\"width: 71.4485%; height: 39.1875px;\"\u003eDependent on installed modules; supports F3PU10-0S\/F3PU20-0S power distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 25.2181%; height: 39.1875px;\"\u003eCoreFunction\u003c\/td\u003e\n\u003ctd style=\"width: 71.4485%; height: 39.1875px;\"\u003eBackplane connectivity for CPU, I\/O, and expansion modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Control Connectivity Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe F3BU13-0N incorporates channel-to-channel isolation across the backplane, minimizing cross-talk between analog and digital I\/O modules. It supports integration with 4-20 mA HART loop instruments and FOUNDATION Fieldbus\/ProfibusPA modules, preserving signal fidelity and ensuring accurate process control. Cold junction compensation (CJC) support is maintained for temperature-sensitive analog channels when linked with compatible FA-M3 analog input modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eQ: VnA: Can modules be hot-swapped in the F3BU13-0N chassis?\u003cbr\u003eA: Only certain expansion and I\/O modules support hot-swap; CPUs and power supplies must be powered down before removal or insertion.\u003c\/p\u003e\n\u003cp\u003eQ: VnA: How is electrical isolation handled between slots?\u003cbr\u003eA: Each slot is electrically isolated with channel-to-channel barriers to prevent signal interference, supporting mixed analog and digital module populations.\u003c\/p\u003e\n\u003cp\u003eQ: VnA: Are firmware updates for CPUs affected by the base module?\u003cbr\u003eA: Firmware flash compatibility is maintained across the backplane; updates should follow the FA-M3 CPU update procedure without additional base module intervention.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44162884796504,"sku":"F3BU13-0N","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/F3BU13-0N-3.jpg?v=1780275995","url":"https:\/\/www.industriaxplc.com\/products\/f3bu13-0n-fa-m3-base-module-yokogawa","provider":"IndustriaX Limited","version":"1.0","type":"link"}