{"product_id":"f3ad08-4v-analog-input-module-yokogawa","title":"F3AD08-4V | Analog Input Module | Yokogawa","description":"\u003ch2\u003eYokogawa F3AD08-4V Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa F3AD08-4V\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eF3AD08-4V\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for converting analog voltage signals into digital data within FA-M3 programmable logic controllers. It directly interfaces with field instruments to provide high-resolution voltage measurements across eight independent channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa F3AD08-4V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 180 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard FA-M3 module size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e0 degC to 55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorageTemp\u003c\/td\u003e\n\u003ctd\u003e-20 degC to 75 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC: 100 mA 24 VDC: 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputChannels\u003c\/td\u003e\n\u003ctd\u003e8 (voltage, non-isolated between channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputSignalRange\u003c\/td\u003e\n\u003ctd\u003e-10 VDC to +10 VDC, 0 VDC to 10 VDC, 1 VDC to 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputImpedance\u003c\/td\u003e\n\u003ctd\u003eApprox. 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximumAllowableInput\u003c\/td\u003e\n\u003ctd\u003e±15 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/DConversionResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit (sign + 15-bit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversionSpeed\u003c\/td\u003e\n\u003ctd\u003eApprox. 100 μs\/channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulationResistance\u003c\/td\u003e\n\u003ctd\u003e≥ 10 MΩ at 500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstandVoltage\u003c\/td\u003e\n\u003ctd\u003e500 VAC, 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternalConnection\u003c\/td\u003e\n\u003ctd\u003e18-point detachable terminal block (M3 screws)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports 4-20 mA HART loop protocol via analog input conversion.\u003c\/li\u003e\n\u003cli\u003eImplements channel-to-channel isolation to reduce signal interference between voltage inputs.\u003c\/li\u003e\n\u003cli\u003eIncludes cold junction compensation (CJC) for sensors that require thermal reference adjustments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the F3AD08-4V support hot-swapping?\u003cbr\u003eA: No, the module is not designed for hot-swap operations and must be powered down before insertion or removal.\u003c\/p\u003e\n\u003cp\u003eQ: Can the module handle voltage signals exceeding the specified range?\u003cbr\u003eA: Input voltages beyond ±15 VDC may damage the module. All signals must remain within the rated range for proper operation.\u003c\/p\u003e\n\u003cp\u003eQ: How is the analog input scaling configured?\u003cbr\u003eA: Scaling is performed via the FA-M3 CPU software using standard analog input setup routines; hardware provides linear voltage-to-digital conversion.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module onto the FA-M3 backplane with proper alignment to avoid connector strain.\u003c\/li\u003e\n\u003cli\u003eEnsure all field wiring is twisted and shielded where possible; connect shields to protective ground at a single point.\u003c\/li\u003e\n\u003cli\u003eAvoid running analog signal lines in parallel with high-voltage or high-frequency power cables.\u003c\/li\u003e\n\u003cli\u003eConfirm that terminal screws are tightened to manufacturer torque specifications to maintain reliable electrical contact.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified ambient temperature and humidity ranges to ensure accurate A\/D conversion and module longevity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44214148661336,"sku":"F3AD08-4V","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/F3AD08-4V.jpg?v=1781057205","url":"https:\/\/www.industriaxplc.com\/products\/f3ad08-4v-analog-input-module-yokogawa","provider":"IndustriaX Limited","version":"1.0","type":"link"}