{"product_id":"esb-bus-node-unit-yokogawa-anb10s","title":"ESB Bus Node Unit Yokogawa  ANB10S","description":"\u003ch2\u003eYokogawa ANB10S ESB Bus Node Unit\u003c\/h2\u003e\n\u003cp\u003eConfigured for I\/O signal interfacing and ESB bus communication in CENTUM VP and CENTUM CS 3000 systems, the \u003cstrong\u003eYokogawa ANB10S-415\u003c\/strong\u003e (\u003cstrong\u003eANB10S\u003c\/strong\u003e ESB Bus Node Unit) provides direct physical and electrical execution for field I\/O data exchange through a single ESB bus architecture. The unit supports N-IO\/FIO integration and serves as the interface layer between control stations and distributed I\/O assemblies.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eANB10S\u003c\/td\u003e\n\u003ctd\u003eNode Unit for Single ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-3\u003c\/td\u003e\n\u003ctd\u003eSingle power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-4\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e100 - 120 V AC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e220 - 240 V AC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e24 V DC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eBasic type with no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 option, -20 to 70 degC option, no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 option, no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003ctd\u003eBasic type with explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 option, -20 to 70 degC option, explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 option and explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e\u003cstrong\u003eOptional Codes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/CU1N\u003c\/td\u003e\n\u003ctd\u003eConnector Unit for ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/CU1T\u003c\/td\u003e\n\u003ctd\u003eConnector Unit with Terminator for ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/ATDOC\u003c\/td\u003e\n\u003ctd\u003eExplosion Protection Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa ANB10S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003eDepends on suffix code; standard type or optional -20 to 70 degC version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eESB Bus Node Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Architecture\u003c\/td\u003e\n\u003ctd\u003eSingle ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible I\/O\u003c\/td\u003e\n\u003ctd\u003eN-IO and FIO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Options\u003c\/td\u003e\n\u003ctd\u003e100 - 120 V AC, 220 - 240 V AC, or 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Option\u003c\/td\u003e\n\u003ctd\u003eSingle or dual-redundant power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion Protection\u003c\/td\u003e\n\u003ctd\u003eAvailable depending on suffix selection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Option\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 coating available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFOUNDATION Fieldbus and Channel Isolation Considerations\u003c\/h3\u003e\n\u003cp\u003eThe ANB10S functions within Yokogawa DCS architectures that support integration of field instrumentation using conventional analog interfaces and digital field communication technologies. When installed with compatible I\/O assemblies, communication paths may support FOUNDATION Fieldbus network segments and conventional 4-20 mA signal loops.\u003c\/p\u003e\n\u003cp\u003eElectrical isolation characteristics are implemented within associated I\/O hardware to reduce channel-to-channel interference and maintain signal integrity between field devices and control applications. Isolation performance depends on the installed I\/O module type rather than the node unit itself.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the ANB10S provide ESB bus redundancy?\u003c\/strong\u003e\u003cbr\u003eA: No. ANB10S is designed for single ESB bus operation. Redundant ESB bus configurations require the corresponding dual-bus node unit model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can different power supply voltages be selected for the same base model?\u003c\/strong\u003e\u003cbr\u003eA: Yes. Power supply voltage is determined by the model suffix code, allowing selection of 100 - 120 V AC, 220 - 240 V AC, or 24 V DC versions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is ISA Standard G3 environmental protection available?\u003c\/strong\u003e\u003cbr\u003eA: Yes. Specific suffix options provide ISA Standard G3 environmental protection, with certain variants also supporting operation from -20 to 70 degC.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the node unit in accordance with the applicable CENTUM system cabinet and rack installation procedures.\u003c\/li\u003e\n\u003cli\u003eMaintain separation between ESB communication cabling and power wiring to minimize conducted electrical noise.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields according to plant grounding standards and Yokogawa installation requirements.\u003c\/li\u003e\n\u003cli\u003eVerify suffix code compatibility before energizing the unit, particularly for power supply voltage and explosion protection requirements.\u003c\/li\u003e\n\u003cli\u003eUse the specified ESB connector units and terminators where required by the network topology.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate cabinet ventilation and environmental conditions consistent with the selected model variant.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44186772799576,"sku":"ANB10S","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ANB10S-3.jpg?v=1780621763","url":"https:\/\/www.industriaxplc.com\/products\/esb-bus-node-unit-yokogawa-anb10s","provider":"IndustriaX Limited","version":"1.0","type":"link"}