{"product_id":"emerson-ve4005s2b3-dk218k-analog-input-card-deltav-s-series","title":"Emerson VE4005S2B3 | DK218K | Analog Input Card | DeltaV S-Series","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson VE4005S2B3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density 8-channel analog input card designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDeltaV S-series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol system. It converts analog signals from field instruments, such as pressure, flow, or level transmitters, into precise digital data for process control. Featuring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHART protocol support\u003c\/strong\u003e, it enables remote diagnostics and calibration of smart field devices without additional multiplexers.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS2 form factor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows quick plug-and-play installation on S-series carriers, while its rugged design ensures reliable operation in industrial environments with wide temperature ranges, vibration, and shock exposure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features \u0026amp; Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHART Integration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports HART v5, v6, and v7 for advanced diagnostics and secondary variable acquisition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnables remote configuration and monitoring of smart field devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Channel Density\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e8 analog inputs in a compact footprint, optimizing panel space\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow-power design reduces heat dissipation, extending hardware life\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eReliability \u0026amp; Redundancy\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHot-swappable module allows replacement without interrupting system operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports redundant configurations for continuous process control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAccurate Signal Processing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed A\/D conversion ensures precise measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in digital filtering mitigates electrical noise and signal interference\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial-Grade Durability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConformal coating protects against moisture, dust, and corrosive gases (ISA-S71.04-1985 Class G3)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShock resistance: 10 g half-sine wave (11 ms)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration resistance: 1 mm peak-to-peak (2–13.2 Hz), 0.7 g (13.2–150 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating temperature: -40°C to +70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable style=\"width: 100%;\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth style=\"width: 26.8953%;\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"width: 72.7437%;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8953%;\"\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7437%;\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8953%;\"\u003e\u003cstrong\u003eInput Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7437%;\"\u003e4-20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8953%;\"\u003e\u003cstrong\u003eProtocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7437%;\"\u003eHART v5, v6, v7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8953%;\"\u003e\u003cstrong\u003eTerminal Block\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7437%;\"\u003e16-pin mass termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8953%;\"\u003e\u003cstrong\u003eField Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7437%;\"\u003eScrew connection, 0.2–4 mm² rigid, 0.2–2.5 mm² flexible, AWG 24–12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8953%;\"\u003e\u003cstrong\u003eController Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7437%;\"\u003eIDC\/FLK pin strip, 16 positions, 2.54 mm pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8953%;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7437%;\"\u003eS-series horizontal carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8953%;\"\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7437%;\"\u003eGalvanically isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8953%;\"\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7437%;\"\u003ePower and error LED indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8953%;\"\u003e\u003cstrong\u003eDimensions (W×H×D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7437%;\"\u003e61 × 126 × 71 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8953%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7437%;\"\u003e239.1 g (excluding packing), 259 g (including packing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8953%;\"\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7437%;\"\u003eUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.8953%;\"\u003e\u003cstrong\u003eCustoms Tariff Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 72.7437%;\"\u003e85369010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMonitoring and control of process variables such as flow, pressure, and temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration with smart HART-enabled field instruments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRedundant control loops requiring uninterrupted operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystems needing high signal fidelity and low-noise analog input\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this card support HART diagnostics on all channels?\u003c\/strong\u003e\u003cbr\u003eA: Yes, every channel supports HART communication for device monitoring and configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is external power required for field inputs?\u003c\/strong\u003e\u003cbr\u003eA: No, the module operates on standard DeltaV system power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the card be replaced without shutting down the system?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it is hot-swappable and supports redundant configurations for continuous operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are there higher density versions of the S-series analog input cards?\u003c\/strong\u003e\u003cbr\u003eA: Yes, Emerson offers additional S-series cards with more channels for larger applications.\u003c\/p\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":44080117219416,"sku":"VE4005S2B3","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/EmersonVE4005S2B3-3.jpg?v=1778220839","url":"https:\/\/www.industriaxplc.com\/products\/emerson-ve4005s2b3-dk218k-analog-input-card-deltav-s-series","provider":"IndustriaX Limited","version":"1.0","type":"link"}