{"product_id":"emerson-ve3008-kj2005x1-mq2-13p0072x092-digital-input-module","title":"EMERSON VE3008 KJ2005X1-MQ2 13P0072X092 Digital Input Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eVE3008 KJ2005X1‑MQ2 (13P0072X092)\u003c\/strong\u003e Digital Input Module is a safety‑rated input component designed for DeltaV SIS process safety systems. Built for high‑integrity signal acquisition, it provides reliable monitoring of discrete field inputs in safety‑critical applications. Its rugged construction, hazardous‑area certifications, and stable electrical performance make it suitable for demanding industrial environments where system protection and operational continuity are essential.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDigital input module for DeltaV SIS architectures\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCertified for hazardous‑area operation (ATEX, IECEx, FM)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports Ex ec and Class I, Div. 2 installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOperates from 5 VDC local bus power at approximately 1.4 A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWide operating temperature range for harsh environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh resistance to shock, vibration, and airborne contaminants\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for long‑term reliability in mission‑critical systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eDigital input module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Bus Power\u003c\/td\u003e\n\u003ctd\u003e5 VDC, approx. 1.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous‑Area Approvals\u003c\/td\u003e\n\u003ctd\u003eII 3G Ex ec IIC Gc, Class I Div. 2 Groups A–D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eATEX, IECEx, FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003ePer DeltaV SIS safety standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemoval Under Power\u003c\/td\u003e\n\u003ctd\u003eNot permitted in hazardous areas unless verified safe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eEnvironmental Ratings\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e−40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e−40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5–95% RH, non‑condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003eUp to 0.7 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e10 g, 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContaminant Resistance\u003c\/td\u003e\n\u003ctd\u003eISA‑S71.04 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eMechanical Data\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.1 × 15.9 × 10.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDeltaV SIS carrier base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eLogistics\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eBrand New\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailability\u003c\/td\u003e\n\u003ctd\u003eIn Stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOQ\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eVE3008 KJ2005X1‑MQ2 (13P0072X092)\u003c\/strong\u003e module is engineered for high‑reliability digital input monitoring within DeltaV SIS safety systems. Designed to withstand extreme temperatures, mechanical stress, and corrosive airborne contaminants, it ensures stable operation in environments where safety‑instrumented functions must remain continuously available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts hazardous‑area certifications allow deployment in facilities handling flammable gases or vapors. The module’s construction supports safe operation under Ex ec and Class I, Div. 2 conditions, making it suitable for refineries, chemical plants, and other high‑risk industrial sites.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe module operates from 5 VDC local bus power and integrates seamlessly into existing DeltaV SIS installations. Although discontinued, it remains widely used in legacy systems due to its proven reliability and compatibility. Strict safety procedures apply: the module must not be inserted or removed while energized in hazardous areas unless conditions are verified safe.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWith its durable design and compliance with international safety standards, the \u003cstrong\u003eVE3008 KJ2005X1‑MQ2\u003c\/strong\u003e continues to serve as a dependable component in mission‑critical process safety applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSafety‑instrumented systems (SIS) requiring digital input monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHazardous‑area installations with explosive gas atmospheres\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEmergency shutdown (ESD) and interlock systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh‑reliability DCS\/SIS hybrid architectures\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLegacy DeltaV SIS system maintenance and expansion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can this module be removed while the system is powered?\u003c\/strong\u003e  A: Not in hazardous areas. Removal under power is only allowed after verifying safe conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is this module still supported in existing DeltaV SIS systems?\u003c\/strong\u003e  A: Yes. Although discontinued, it remains widely deployed and supported in legacy installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What certifications does the module carry?\u003c\/strong\u003e  A: It meets ATEX, IECEx, and FM requirements for hazardous‑area operation.\u003c\/span\u003e\u003c\/p\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":43224375099480,"sku":"VE3008 KJ2005X1-MQ2 13P0072X092","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/emerson-ve3008-kj2005x1-mq2-13p0072x092-digital-input-module-0lb2duweo1o.png?v=1758523822","url":"https:\/\/www.industriaxplc.com\/products\/emerson-ve3008-kj2005x1-mq2-13p0072x092-digital-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}