{"product_id":"emerson-se4304t01-deltav-do-24v-dc-isolated-charm-module","title":"EMERSON SE4304T01 DeltaV DO 24V DC Isolated CHARM Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSE4304T01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eby\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEMERSON\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a DeltaV digital output (DO) CHARM module designed for 24 V DC inductive load control. It provides reliable, isolated output channels with configurable behavior for both momentary and continuous pulse operations. Its built-in protections and galvanic isolation ensure safe, durable performance in demanding industrial environments.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports 24 V DC inductive loads with continuous 1.0 A output and 2.0 A inrush for short periods (\u0026lt;100 ms)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput voltage range: 4 V DC to 32 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGalvanically isolated output channel, factory-tested to 1000 V DC for maximum signal integrity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigurable output behavior: momentary output or continuous pulse output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated field circuit protection: 4 A current limiting with thermal shutdown and automatic reset\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRecommended external fuse at power source for additional safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow CHARM power consumption: 22 mA max at 24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMinimal heat dissipation: 0.46 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSE4304T01\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003e24 V DC Inductive Load CHARM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e4 V DC to 32 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output Current\u003c\/td\u003e\n\u003ctd\u003e1.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e2.0 A (\u0026lt;100 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Leakage Current\u003c\/td\u003e\n\u003ctd\u003e≤1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Behavior\u003c\/td\u003e\n\u003ctd\u003eConfigurable: Momentary or Continuous Pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanically isolated, 1000 V DC factory-tested\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Circuit Protection\u003c\/td\u003e\n\u003ctd\u003e4 A current limiting, thermal shutdown, automatic reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Protection\u003c\/td\u003e\n\u003ctd\u003eExternal fuse at power source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCHARM Power Requirement\u003c\/td\u003e\n\u003ctd\u003e22 mA max @ 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e0.46 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eDesigned for industrial systems requiring precise, isolated digital outputs. Common applications include process control, chemical plants, oil \u0026amp; gas operations, and power generation systems where inductive load management and output protection are essential.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum continuous output current?\u003c\/strong\u003e\u003cbr\u003eA: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSE4304T01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports 1.0 A continuous output with a 2.0 A inrush for less than 100 ms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is the module protected against overloads?\u003c\/strong\u003e\u003cbr\u003eA: Integrated 4 A current limiting with thermal shutoff and automatic reset protects the module, while an external fuse is recommended for added safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the output be configured for different behaviors?\u003c\/strong\u003e\u003cbr\u003eA: Yes, outputs can be set for momentary or continuous pulse operation based on system requirements.\u003c\/p\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":44072260141144,"sku":"SE4304T01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/EmersonSE4304T01.jpg?v=1778064260","url":"https:\/\/www.industriaxplc.com\/products\/emerson-se4304t01-deltav-do-24v-dc-isolated-charm-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}